Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Opal_Set_Acq_Trigger

Sets the acquisition trigger dynamically during the simulation. Data will be acquired only when a specific signal is triggered.

The option of starting data acquisition only once a specified threshold is reached allows users to obtain information about a specified time-slice of the simulation. If a block OpTrigger is present in the model when activating the dynamic acquisition, the triggering will be set to the value of parameters provided by OpalSetAcqTrigger.

When the parameter triggerEnabled in the OpalSetAcqTrigger interface is set to false, the block OpTrigger will regain the triggering control once again.

Required Control

Acquisition Control

Opal_Set_Acq_Trigger

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323