Documentation Home Page Courseware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

LAB 2 - Panel

When starting the demo, the panel in figure 13 below appears first with the default settings.



Figure 13: Start-Up Panel of Buck Converter Laboratory

For operation of the buck converter panel, the student can refer to the panel operation of the boost converter, because the panels of both models are very similar.
The differences in control parameters, content of scopes, and nameplate ratings for the buck converter are presented in tables 14 to 16 below.

Control Parameters

Default Value

Interval of Variation

DC Source Voltage (V)

100

[0; 400]

Switching Frequency (Hz)

1500

[1500; 3600]

Duty Cycle

0.5

[0.1; 0.9]

Inductance (mH)

100

50 or 100

Capacitance (µF)

400

400 or 800

Table 14: Control Parameters of the Buck Converter

Scope

Content of Scopes & Displayed Waveforms

Scope11

Load output voltage and switching signal (multiplied by a factor of 5)

Scope21

Input current of the DC source and inductor current

Scope12

Load output current

Scope22

Input power of the DC source and load output power

Table 15: Content of Scopes and Displayed Waveforms in Buck Converter Laboratory

Nominal Power

10 kW

Input Voltage

[0; 400] V

Output Voltage

[0; 360] V

Output Current

[0; 28] A

Table 16: Buck Converter Nameplate Ratings

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323