Squirrel-cage Induction Motor - Panels

Documentation Home Page Courseware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Squirrel-cage Induction Motor - Panels

Understanding the Panel

When starting the demo, the panel in figure 7 appears first with the default settings.


Figure 7: Start-Up Panel of the Induction Motor Drive Laboratory

The panel is to be operated as follows:

  • In the upper left corner, under DC Machine (DCM), the student can set the field voltage of the DC machine and can change the value of the resistive load.

  • In the middle left corner, under Command, the student can select the type of control to be applied to the induction motor.

  • Under each command tab, there are control parameters and/or control buttons that are summarized in tables 4 and 5.

  • Once a control is selected and applied, the student can observe the related waveforms under Oscilloscopes.
    More details about the displayed waveforms are discussed later.

Table 4 summarizes the control parameters, while table 5 is dedicated for the control buttons.

Control Parameters

Tab

Default Value

Interval of Variation

Control Parameters

Tab

Default Value

Interval of Variation

DCM Field Voltage (V)

DC Machine (DCM)

0

[0; 460]

DCM Variable Load (Ω)

DC Machine (DCM)

0

[0; 20]

Inverter frequency (Hz)

Command V/F

0

[0; 60]

Reference torque (Nm)

Torque Control

0

[-55; 55]

Reference speed (rpm)

Speed Control

0

[-2500; 2500]

Table 4: Control Parameters of the IM Drive

Control Buttons

Associated functions

Control Buttons

Associated functions

TRIGGER

The waveforms are not triggered. They “move”

The waveforms are triggered with respect to a reference signal.

This button is accessible only for the V/F Control Oscilloscopes.

V/F control

V/F control is disabled.

V/F control is enabled.

This button is accessible in V/F Command only.

Reset

The reset push button is disabled.

The reset push button is activated and simulates replacement of fuses after a fault.

This button is accessible and enabled in all scenarios

ACTIVATE

Flux control is disabled.

Flux control is enabled.

This button is accessible in Flux Control only.

enable

Torque control is disabled.

Torque control is enabled.

This button is accessible in Torque Control only.

ENABLE

Speed control is disabled.

Speed control is enabled.

This button is accessible in Speed Control only.

Fia

The DC machine’s armature fuse is blown.

The DC machine’s armature fuse is intact.

Fif

The DC machine’s field fuse is blown.

The DC machine’s field fuse is intact.

Fi1

The induction machine’s stator phase 1 fuse is blown.

The induction machine’s stator phase 1 is intact.

Fi2

The induction machine’s stator phase 2 fuse is blown.

The induction machine’s stator phase 2 is intact.

Fi3

The induction machine’s stator phase 3 fuse is blown.

The induction machine’s stator phase 2 is intact.

Control Choice

Allow to implement the flux, torque, and speed controllers manually (User) or automatically (Predefined).