Documentation Home Page ◇ Courseware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
PVGS - Panels
Page Content
Understanding the Panel
When starting the demo, the panel in figure 6 appears first with the default settings.
Figure 6: Start-Up Panel of the Photovoltaic Generation System Laboratory
The panel is to be operated as follows:
- In the top left corner, under Operation Modes, the student can select (via the switch button) to operate the PVGS either as MPPT or curtailment mode.
- In the middle left corner, under Setpoints, the student can change the control parameters, which are summarized in table 1.
Control Parameters | Default Value | Interval of Variation |
---|---|---|
Irradiance E (W/m2) | 950 | [0; 1000] |
Active Power Reference Pref (p.u.) | 0.5 | [0; 1] |
Reactive Power Reference Qref (p.u.) | 0 | [-1; 1] |
Temperature (oC) | 25 | [0; 60] |
Table 1: Control Parameters of the PVGS
After setting the control parameters, the students can observe the waveforms displayed in six scopes.
More details about the displayed waveforms are given in table 2.
On scope localization, the indices used will be like those of matrix elements.
Hence, the first under PV Array Measurements, located in the upper left corner (first row, first column) is denoted Scope11, while the second scope under PV Array Measurements in the upper right corner (first row, second column) is Scope12.
By the same token, the four scopes under System Measurements are denoted Scope21, Scope22, Scope31, and Scope32.
Scope | Content of Scopes & Displayed Waveforms |
---|---|
Scope11 | PV voltage VPV measured at the PV cell. |
Scope12 | PV current IPV measured at the PV cell. |
Scope21 | Voltage Va and current Ia measured between the three-phase inverter and the transformer (see figure 7 below). |
Scope22 | DC link voltage Vdc measured at the DC link (see figure 7 below). |
Scope31 | Active power reference Pref and active power of the PVGS. |
Scope32 | Reactive power reference Qref and reactive power of the PVGS. |
Table 2: Content of Scopes and Displayed Waveforms
Figure 7: Components of the Photovoltaic Generation System
Help Tab
When clicking on the “Help Contents” tab, the panel in figure 8 is displayed.
In this panel, the student can see live displays of RMS currents and voltages, and power flow at different parts of the PVGS.
The student can validate the simulation results by checking that the power flow is balanced.
Figure 8: Help Contents Panel of the Photovoltaic Generation System Laboratory
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter