Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
FPGA-Based Circuit
Mask and Parameters
- Name: Name of the electrical circuit to be loaded
- Edit: Open the selected model in the dedicated schematic editor
- Create new: Open a new empty model in the Schematic Editor
- Load circuit: Load the selected circuit in the HYPERSIM model and automatically redraw the block and generate the I/O and FPGA configurations
- Source: Allow to choose whether to select parameter sets from the component "Active Set" parameter or from an internal signal connected to the parameter_set_id pin
- Active set: Current active parameter set. To actually update the active set, the "Apply" button needs to be pressed
Ports, Inputs, Outputs and Signals Available for Monitoring
The inputs and outputs of this model are generated dynamically depending on the sources, switches and measurements present in the FPGA-based model.
Additionally to these inputs/outputs a parameter_set_id pin allows controlling the parameter set selection from the CPU model.
Ports
Network connections are not supported at the moment.
Inputs
- Controlled sources inputs: drive the controlled current and controlled voltage sources from the FPGA-based model
- Switches inputs: control the switches from the FPGA-based model
- parameter_set_id: Parameter set ID. Only used by the component if the parameter set source is set to "External"
Note: if parameter_set_id value is not valid, the previous valid value will be used
Outputs
- All outputs represent measurement components placed in the FPGA-based circuit
Sensors
All input and output pins are also available as sensors for monitoring in ScopeView.
Parameter Sets
Parameter sets allow changing multiple FPGA-based circuit's component parameters during the simulation, without having to re-flash the firmware or stop and restart the simulation. Parameter set values, names and ID can be defined from the schematic editor while editing the FPGA-based circuit. As mentioned above, as with any HYPERSIM component parameters, in order to update the active set during the simulation the "Apply" button must be pressed.
Troubleshooting
When clicking Load circuit, the configuration files are automatically generated in the model _hyp folder. Thus, to properly share a model using an FPGA-based circuit component, one has to copy the _hyp along with the .ecf file.
In the case where loading a circuit fails, a notification message appears. This message is clickable and a popup with more information about the failure is displayed:
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323