Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Network Filters

Introduction

Passive filters are elements showing an identical impedance in different resistance-inductance capacitor combinations series or parallel connected. Even though these can be represented with simple passive elements, using filters has the advantage of eliminating nodes between components, thereby decreasing the number of nodes or the size of the Z matrix in the station where they are found. Meaning that the station simulation time is also decreased.

There are five types of filters available in HYPERSIM®, each offering both a series and grounding connection option:

Filter Type

Description

Filter Type

Description

C-Type

The series C-type filter is available both for 1-phase and 3-phase connections. 

C-Type Grounded

The grounded C-type filter is available both for 1-phase and 3-phase connections.

Double-Damped

The series double-damped filter is available both for 1-phase and 3-phase connections. 

Double-Damped Grounded

The grounded double-damped filter is available both for 1-phase and 3-phase connections.

Generic RLC

The series generic RLC filter is available both for 1-phase and 3-phase connections. 

Generic RLC Grounded

The grounded generic RLC filter is available both for 1-phase and 3-phase connections. 

High-Pass

The series high-pass filter is available both for 1-phase and 3-phase connections.

High-Pass Grounded

The grounded high-pass filter is available both for 1-phase and 3-phase connections. 

Series-Parallel RLC

The series series-parallel RLC filter is available both for 1-phase and 3-phase connections.

Series-Parallel RLC Grounded

The grounded series-parallel RLC filter is available both for 1-phase and 3-phase connections. 



OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323