Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Advanced | SITSEUIL

THRESHOLD TIME – [SITSEUIL]
Compute the time at which a threshold value is reached.


CATEGORY
Advanced

DESCRIPTION
Compute the time at which a threshold value is reached (either on positive or negative slope) on a specified part of a signal.


RESULT VARIABLES AND PARAMETERS

ResultTime in milliseconds [ms] at which the threshold value is reached on the specified part of the signal, increased by the delay and multiplied by the factor. If the returned result is HUGE, this means that the threshold value was never reached within the set limits
Note that the returned time is really the time at which the threshold value is reached, increased by the delay, and not the time relative to the starting time of the analysis.
SignalSignal to analyze.
Signal_PartPart of the signal on which the analysis is done (neg, pos, sig, abs).
Here are the definitions for the four distinct parts of a signal:
Neg
  • Only the negative values of the input signal are used for the calculations. The other values are considered to be null.

Pos

Only the positive values of the input signal are used for the calculations. The other values are considered to be null.


Sig 

The original input signal is used for the calculations.

Abs 

The calculations are done on the absolute value of the input signal.

ThresholdValue of threshold to be reached on the specified part of the signal.
DelayWhen the threshold time is determined, a delay is added to it. The new starting time of the analysis is thus equal to the time taken to reach the threshold plus the delay. The delay is specified in milliseconds [ms].
Begin_timeTime at which the analysis of a signal must start. This time is expressed in milliseconds [ms]. This value must be greater than 0 and lower than the duration of the test. The default value is 0.
End_timeTime at which the analysis of a signal must end. This time is expressed in milliseconds [ms]. The value of this time must be larger than the specified begin_time and smaller than the duration of the test. Use the “HUGE” value to specify the end of the test. The default value is HUGE.
FactorMultiplying factor for the results generated by the function. The default value of the multiplying factor is 1.0 and has no effect on the results.


SYNTAX

res = sitseuil( input, "sig", 0.5, 0, 0, HUGE, 1)


CHARACTERISTICS
Data type support
Double Floating point


EXAMPLE
The following figure shows the different cases which can arise when executing the sitseuil function.

  • Begin Time: Instant after which the function computes the time.
  • Pictorial Representation:

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323