Misc. | POWER3PH
3 PHASE POWER – [POWER3PH]
Computes the active and reactive power of a three-phase element by using voltages and currents.
This function assumes a direct sequence for the phases. The sequences can be set directly in the sources' mask.
CATEGORY
Miscellaneous
DESCRIPTION
This function allows to compute the active power and reactive power by using phase to ground voltages and currents signals. The inputs are transformed into direct sequence element and then the power is computed:
RESULT VARIABLES AND PARAMETERS
Active Power | Active power of the input signals |
Reactive Power | Reactive power of the input signals |
V_A | Input voltage, phase A |
V_B | Input voltage, phase B |
V_C | Input voltage, phase C |
I_A | Input current, phase A |
I_B | Input current, phase B |
I_C | Input current, phase C |
Fundamental Frequency | Fundamental frequency of the inputs |
Nominal Power | Nominal power of the network. This factor will divide the power displayed in ScopeView. Note that the unit of the graphic will not be updated. |
SYNTAX
[p,q]=power3ph(Bus_Va,Bus_Vb,Bus_Vc,Load_Ia,Load_Ib,Load_Ic,60,1)
CHARACTERISTICS
Data type support
Double Floating point
EXAMPLE