Documentation Home Page ◇ Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OP5705XG IO Connectors
LEGACY PRODUCT
Please note that OPAL-RT is no longer selling this product. Current users will continue to receive support until December 31, 2028.
For details about support, please refer to the End-of-Life Announcement. For any other questions, please contact your OPAL-RT sales representative.
Page Contents
DB37F Connectors
Analog I/O Modules
Each pair of I/O modules (A & B) is linked to four (4) female DB37 connectors (I/Os) on the back of the chassis:
The first two connectors (left to right) represent channels from Group B, which are linked to the conditioned channels from the rear I/O module.
The last two connectors (left to right) represent channels from Group A, which are linked to the conditioned channels from the front I/O module.
If the front I/O module is an analog module (DAC or ADC), the 16 channels are on connector A and connector B does not carry any signals.
If the back I/O module is an analog module (DAC or ADC), the 16 channels are on connector C and connector D does not carry any signals.
Digital I/O Modules
If the front I/O module is a digital module (Din or Dout), the first 16 channels (00 to 15) are on the first connector, and the next 16 channels (16 to 31) are on the second connector.
If the back I/O module is a digital module (Din or Dout), the first 16 channels (00 to 15) are on the first connector, and the next 16 channels (16 to 31) are on the second connector.
All signals are represented by a positive-negative pair that are always available on the connector pins, for example: for channel 08 : (08+, -08)
Positive/Negative Signals Connection
For a single-ended output, the negative conductor is connected to Ground
For a differential output, the positive and negative signals are on the connector
For a differential input, the connection must be between the positive/negative pair
If the input is single-ended, user’s ground must be connected to the negative side of the pair
RJ45 Connectors
Each RJ45 monitoring panel on the front of the OP5705XG simulator connects to front and back I/O modules.
The following images illustrate how the I/O modules are linked to the connectors.
OP5705XG Rear (DB37)
RJ45 Channel Assignments
Each I/O module is assigned two columns of RJ45 connectors.
Each column represents a series of channels, divided into 4 channels per jack, as shown in the figure below.