HIL2GO-410 - System Power On and Power Off Sequences
Page Content
TARGET COMPUTER RE-BOOT WARNING: Follow the Power On/Off sequence as indicated below. Failure to do so may require rebooting of the Target.
Power on Sequence
Power on the OP4810-IO
Power on the OP5025XG
If the OP525XG (which is running HYPERSIM on the target) is powered on before the OP4810-IO, HYPERSIM won't be able to detect the present of OP4810-IO FPGA Processor and I/O Expansion Units.
Power off Sequence
Power off the OP5025XG
Power off the OP4810-IO
Disconnecting or powering off the OP4810-IO during operation will require a power off sequence followed by a power on sequence in order to resume reliable operation.