3.3 Configuring the Electrical Models

Circuit Model File Path: <Public Documents>\National Instruments\<NI VeriStand 20XX>\Examples\OPAL-RT\Power Electronics Add-On\PMSM SH Local Control\Circuit Model\PMSM_eHS_UB.mdl

 

Configuring the PMSM Model

In this example, the PMSM model and associated sensors have been pre-configured. For more information related to machine configuration, please refer to the PMSM SH Section. Explore the configuration of the machine by following the steps below.

  • In the Configuration Tree, expand Circuit Model >> Machines and click PMSM SH 1 to open the configuration page for the machine.

  • Observe the configured machine parameters. The Input Mapping subsection allows the outputs of the circuit model to be connected to the inputs of the machine.

  • In the Configuration tree, expand PMSM SH 1 and click Mechanical Model to view the mechanical model parameters.

  • Confirm that the parameter values match those in the table below.

Machine Configuration

Machine Configuration

Model File

<Public Documents>\National Instruments\NI VeriStand 20xx\Examples\OPAL-RT\Power Electronics Add-On\Dual PMSM SH Local Control\RTT Files

Solver Timestep

4E-7

Table Max Current

-1

DQ Angle Offset

0

Input Mapping Configuration

Voltage Phase A

Circuit Model 1.Va_inv

Voltage Phase B

Circuit Model 1.Vb_inv

Voltage Phase C

Circuit Model 1.Vc_inv

 

 

Mechanical Model Configuration

Mechanical Model Configuration

Initial Rotor Angle (Deg)

0

Viscous Damping

0.001

Static Friction

0

Inertia

0.01

Mechanical Model Mode (VeriStand Channel)

1

 

 

 