2020.3
Support of targets with more than 32 cores
Changed error message when the number of cores allocated for the model is not enough
Added notification that 'BlockReduction' parameters are set to on in a model
LabVIEW: Panels are deactivated by default when running a model on the new OS. (To make them available, add the environment variable: RTLAB_FORCE_LABVIEW_PANELS_ACTIVATION to 1)
LabVIEW: Changed version of LabVIEW panels in example model to 2013 (instead of 2017)
MinGW 9.2: Automatically installed with RT-LAB installer
MinGW 9.2: Default compiler for Windows simulation
Model Compilation: Improved time spent in 'code generation' by specifying the following variables PARAM_VECTOR_SIZE_LIMIT et SIGNALS_VECTOR_SIZE_LIMIT
Model Compilation: Improved time spent in 'Signal database creation'
Removed 'Exit and reconfigure for 10.x' from the File menu of RT-LAB
Dinamo is no longer supported
Documentation: Updated 'Analog Out' documentation
Documentation: Updated internal help links of RT-LAB
Python RT-LAB API: Reset frame configuration of a signal group, after a disconnection, in order to not use the previous configuration entered
Python RT-LAB API: Support for Python 3.8 for RT-LAB & Datalogger Python API
Removed obsolete OP5110-5120, OP5130 and ML506xsg I/O blocks
Removed obsolete OHCI real-time communication link type
CAN: added the option to activate or deactivate connection points for status and flags
OPAL-RT Board: Bitstream of FPGA is reloaded only when the configuration parameters impose it
Orchestra TCP: The first set of features implemented
EtherCAT Master: Added support for Beckhoff FC1100 card
Added validation for the network interface when executing models using C37.118 Master/Slave, IEC61850, Modbus Master/Slave, SCPI or TCP-UDP protocols on Windows
Removed support for SigWire-based FPGAs
Bug Fixes
2020.3
Improved CAN dbc import
Optimized memory used by RT-LAB
Fixed bug related to Recorders when renaming subsystem
Fixed IO duplicate in Project Explorer of RT-LAB
Fixed crash when closing a project or RT-LAB
Removed configuration of a removed Recorder
Fixed manual subsystem assignment, when using Dolphin card
Target: Fixed target status displayed
Target: Fixed reboot or shutdown of a target from RT-LAB
Model Compilation: Force model separation when changing the compiler
ScopeView: Fixed ScopeView help opening
LabVIEW: Fixed frozen of panels when having more than one
LabVIEW: Fixed RT-LAB crash when opening/closing panels
LabVIEW: Fixed Start/Close of RT-LAB when using the panels
Python RT-LAB API: Fixed bugs when creating two 'SignalGroup' object to the same recorder
CAN: Fixed gain not being applied for reception messages
CAN: Fixed minimum value missing when importing a DBC file
CAN: Fixed the issue with bit data types
OPAL-RT Board/MMC: Fixed which connection points appear for each MMC item
OPAL-RT Board: Fixed behavior when input connections are not used in the same subsystem as output connections
Modbus Slave: Fixed usage of Float32 data type for Holding Registers