New features
Added support for Matlab/Simulink R2022A
Added new Simulink block (OpDilInterface) available in rtlab simulink library for mapping simulink bus to RT-LAB inputs and outputs (communication protocols, Orchestra, electrical I/O)
Orchestra: data can be exchanged between the framework and the client using bus/structure hierarchy
FMI: improved the integration of FMU using Orchestra cosimulation framework
License: demo license can now be requested using the new fields of the license request form
Data recording: recordings in oprec file format can now be loaded in Matlab without previous file format conversion (cf. Exploiting OPREC files with MATLAB)
Build/Compilation: default gcc options changed from -O2 to -O3 for better performance
ePHASORSIM: Added LimiterExciterUEL1, LimiterExciterUEL2 , LimiterExciterMAXEX1 and LimiterExciterMAXEX2 in PowerFactory's DGS netlist support
OPAL-RT Board: keep common configuration elements when changing bitstream configuration file
OPAL-RT Board: keep interface configuration when changing chassis type
OPAL-RT Board: add support for the following PWMOUT features : (allow disabling channel, dynamic phase shift and dead time, extended frequency range)
OPAL-RT Board: add support for 64 ports LoadIN/LoadOUT
FPGA SFunctions: add support for the following PWMOUT features : (allow disabling channel, dynamic phase shift and dead time, extended frequency range)
SYNCHRONIZATION: add C37.238-2017 sync profile for Oregano
SYNCHRONIZATION: add support for Oregano card revision 2.3 (OPAL-RTLinux x64-based)
SYNCHRONIZATION: add the option to configure the Oregano card by an OS service launched at boot time
SYNCHRONIZATION: add the possibility to apply an offset on the timestamp received from the Oregano card
PICKERING: add support for LXI (TCP based) type chassis
IEC61850: add support for the control functionality (attributes with CO functional constraint)
AFDX: add support for firmware version 5.1 for the PCIe-C664-V2 card
MODBUS SLAVE: add possibility for a slave to connect to multiple masters
MODBUS SLAVE and MASTER: add the support for INT32, UINT32 and INT16
TCP-UDP: add the IP aliasing feature
CAN: add default arbitration bit rate 500kbps [SP 80%]
CAN: add custom arbitration bit rate
CAN: update custom data bit rate computing (include prescaler value in the computation)
Communication protocols: make NIC field case unsensitive
Bug fixes
Fixed data recording issue when including vector signals
Orchestra: Fixed Orchestra client initialization issue if the Orchestra framework is only loaded and not running
Fixed loss of file transfer configuration when re-compiling the RT-LAB model
ePHASORSIM: Added support of exciters (AC7B, AC8B, ESAC2A, EXAC3, IEEET2, IEEET3), TurbineGovernor (TGOV3, WSHYDD, WSHYGP) in Excel configuration sheet
Processor cores dedicated to the operating system are removed from the list of cores available for real-time simulation
Carriage return in opComm simulink block names are now detected and an error message is displayed
Better management of the 'close project' action when called during model build and compilation
Using free version of Oracle Java JDK/SE
IEC61850: In the MMS server, only create the attributes that are found in the SCL file
IEC61850: Fixed sampled values id used in the packets sent by the simulator
IEC61850: Improve parser to respect the structure data attributes order as defined in SCL file.
MODBUS: Fixed data integrity issue for Holding register data
IEC60870-5-104 SLAVE: Fixed issue when more than 100 slaves are defined
FPGA SFunctions: Ensure that IO blocks are in the same subsystem as their controller
FPGA SFunctions: Fixed issue when OpShare Memory Ctrl is used accross multiple models on the same Target
FPGA SFunctions: Fixed failure to load models containing OpLnk blocks
CAN: Fixed motorola endianness support for CAN-FD
CAN: Fixed the display in the UI of data imported from a dbc
FPGASCOPE: Fixed issue when the signal chosen as trigger is not selected
FPGASCOPE: Fixed process cleaning when the simulation is reset
Deprecation and Removals
Matlab/Simulink R2016A, R2016B, R2017A, R2017B : end of support
OPAL-RTLinux (x86-based 32 bits) : end of support in 2024 (further info at https://www.opal-rt.com/32-bit/)
Windows 7 : end of support scheduled for the next major release
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter