EXata CPS Configurator
This I/O Interface is only compatible with an Opal-RTLinux 3 platform.
Description
The EXata CPS Configurator is an I/O interface used exclusively for linking network interface cards to EXata. Therefore, it does not have a timing impact in the real-time simulation. Since EXata CPS 1.1, it is mandatory to link a network interface card to EXata for license verification.
Also, linking it to a network interface enables to reach an external device on the network (hardware-in-the-loop capability).
For more information on how to use EXata with RT-LAB, please refer to the section EXata CPS.
General Configuration
EXata Network Interface | Enter the network interface card to be linked with EXata. The network interface will be migrated into the network namespace of EXata during the load of the model. A proper interface name should be selected based on the information given by the Linux command "ip a". If the network interface name does not exist, the load of the model will fail. This network interface will become unavailable to the system during the simulation. Make sure that it is not used by another application. |
Add ARP Entry | With this option enabled, the next two parameters IP Address and MAC Address must be configured according to the external device to be reached. An ARP entry will be added to the EXata network interface, increasing the chance to reach the external device. |
IP Address | Only configurable if Add ARP Entry is enabled. This field corresponds to the IP address of the external device to be reached. |
MAC Address | Only configurable if Add ARP Entry is enabled. This field corresponds to the MAC address of the external device to be reached. |
Project Configuration
The configuration of the EXata CPS Configurator will only be taken into account if one of these I/O interfaces is configured with a virtual Ethernet adapter.
- C37.118 Slave and Master
- IEC 60870-5-104 Slave
- IEC 61850 with GOOSE subscribers or publishers. Sampled Values are not supported with EXata CPS
- Modbus Slave and Master
- OPC UA Server
- TCP-UDP
Please refer to EXata CPS documentation for more information on how to configure an I/O interface with EXata.