Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Reset

Group

Model Execution

Description

Stop and reset the current simulation.

Required Control

System control

Usage

RtlabApi.Reset()

Input

None

Output

None

Exception

  • EOK: Success.

  • EPERM: System control had not been granted to this client.

  • EBADF: Model not specified by previous Connect or OpenProject.

  • EIO: Error sending the request or receiving the reply.

  • EEXIST: RT-LAB detected that the model did not reset correctly. Clean-up of processes left running was performed

  • OP_API_MODEL_IO_TIMEOUT: Timed out waiting for reply from model.

  • OP_API_MODEL_IO_ERROR: Model is missing some or all processes or subsystems.

Examples

See example basic_example2.

Related Items

Load, GetSystemControl.