Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

LoadConsole

Group

Model Interaction, Console

Description

Load on the client machine the console subsystem associated with the current connected model. Upon successful return, the console is opened. Only Simulink consoles are supported.

Please note that this function is only available on Windows operating system when the model contains a console subsystem. Furthermore, if the model is a Simulink model, the client machine must have Matlab installed.

Required Control

None

Usage

RtlabApi.LoadConsole()

Input

None

Output

None

Exception

  • EOK: Success.

  • EINVAL: not a Simulink model.

  • EIO: Error sending the request or receiving the reply.

  • EBADF: Model not specified by previous Connect or OpenProject.

  • ENOENT: the model path and/or name is NULL.

  • EACCES: cannot access the modelname.subsys file (this file is generated during the model’s compilation).

  • OP_API_SEPARATION: the model doesn’t contain a Simulink console subsytem or the format of the *.subsys file is incorrect (this file is generated during the model’s compilation).

  • EDOM: model version is different from Simulink version.

  • ERANGE: model version is not compatible with MATLAB version.

Examples

None

Related Items

ExecuteConsole, PauseConsole, ResetConsole, StopConsole

Modules

import RtlabApi

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323