Documentation Home Page ARTEMiS Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

ARTEMiS 7.4

Complete list of changes in ARTEMiS 7.4.0 

  • Compatibility with RT-LAB 11.4.0
  • Support Matlab R2018a, R2018B
  • New SSN Wideband model (2-4-6 phase available) with simple fitter data input; the model has been validated with Hypersim
  • New Marti FD-line model (3 phase only, beta) with simple fitter input.
  • New SSN Wideband fitter GUI for lines and cables. Cable option is new and is made from Hydro-Quebec Crinoline routines. The Fitter GUI produces a (.dat) fitting file directly usable by the new Wideband model of SSN.
  • New demo and new beta block of 3-phase Distributed Parameter Line with variable fault position. This demo is made with SSN methodology: losses are now exactly split on both sides of the fault (as opposed to the similar non-SSN model which assumes a 50/50 repartition for all fault positions) R2015a+ only
  • Added demo: MMC HVDC link using TSB-type model (model coming directly from the MMC blockset)
  • Added demo: MMC HVDC link using SSN User-Custom-Model in one station; gives better accuracy than TSB-type in rectifying modes
  • Fix of Active Distribution Grid with High Penetration of Distributed Generation using SSN
  • Fix of SSN Dynamic load demo: now using low pass filter in RL calculation for improved stability
  • Fix of SSN Synchronous machine models (with and without a neutral terminal), 6th order
  • Fix of SSN Parallel RLC and SSN Series RLC blocks: corrected delay on B matrix, similarly done in SSN machines in earlier fixes
  • Fix of OLTC SSN model in artemis.mdl for proper automatic S-function building
  • Fix of Simple inductance SSN demo
  • Added documentation about line/cable model selection and fitters.