Documentation Home Page ARTEMiS Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

ARTEMiS 7.2

7.2.3

Complete List of Changes in ARTEMiS 7.2.3

  • Compatibility with RT-LAB 11.2.3
  • Renamed SSN Ground Referencing Resistor block.
  • Fixed certain RT-LAB compatible online demos: ssn_9LevelDrive_xfozigzag, ssn_DFIM_wind_turbine_with_crowbar and SSN_IEEE_123Node.
  • Added documentation for Artemis decoupling blocks and editable sample time.
  • Correction to SSN resistance model.

7.2.2

Complete List of Changes in ARTEMiS 7.2.2

  • Compatibility with RT-LAB 11.2.2
  • Compatibility MATLAB 2011b, 2015a-SP1 (prefered version), R2016b, R2017a (64 bits)
  • SSN solver and discretization methods are now used for all-electric subsystems, even if the model is not modeled with SSN (flag DISABLE_SSN_FOR_NON_SSN_MODELS can be used to use old state-space S-function)
  • SSN initial conditions now set to 0 automatically
  • Added scientific paper section to the demos
  • Added benchmark section to the demos
  • New Kundur 4-machine, 2-area model with SSN synchronous machine
  • New IEEE 123 node test feeder using SSN demo
  • SSN printout of matrix invertibility condition number when USE_MFILE_SSN_SFUNCTION=1 is set in the workspace
  • Updated 3 winding 3-phase OLTC transformer demo using SSN: now without S-function builder block.
  • Bipolar HVDC with switched filter banks online demos modified to have a better numerical response with LDLT solver.
  • 3-level NPC TSB model: ground connections are now implicit.
  • Code correction in SSN-OLTC model v2 (without S-function)
  • New SSN demo containing distributed parameter line with breakers and faults at both ends

7.2.1

Complete List of Changes in ARTEMiS 7.2.1

  • Compatibility with RT-LAB 11.2.1
  • Major scientific papers at ARTEMiS-SSN now accessible in the on-line demo section
  • SSN benchmarks accessible in the on-line demo section
  • Various small corrections to demo models
  • RT-LAB snapshot functionality for Simscape Power Systems sfun_discreteVariableDelay S-Function. This allows support for the following blocks: in powerlib_meascontrol/Measurements: Fundamental(PLL-Driven), Mean(Variable Frequency), Positive-Sequence(PLL-Driven), Power (PLL-Driven, Positive-Sequence); and also in powerlib_meascontrol/PLL blocks.

7.2.0

Complete List of Changes in ARTEMiS 7.2.0

  • Compatibility with RT-LAB 11.2
  • Compatibility MATLAB 2011b, 2015a-SP1 and R2016b (prefered versions)
  • New LDLT Factorization option in SSN to improve real-time speed.
  • Adding Delayed Speed Term option in most SSN rotating machine models (SM, DFIM, and PMSM)
  • Major bug correction for SSN solver affecting Rotating machine models mainly: the model admittance matrix was copied in the global system admittance matrix in a transposed way. The copy of the admittance matrix is now correctly done. This only affects machine models, without delayed speed terms, because these have asymetric matrices.
  • Model corrections to SSN-SM and SSN-DFIM to have a delayed discrete B matrice used during SSN model calculation. This delayed B matrice corrects a discrepancy between internally computed current and external ones in the case with the machine connected to very small loads.
  • Model updates for SSN-SM: more measurements available
  • New SSN Custom models available: Parallel RLC, Series RLC, R, all with on-line changeable RLC parameters.
  • New Reconfigurable breaker model available with script and demo. Using this model, one can turn breakers into fixed/closed circuits using a single model running multiple test scenarios.
  • Installer correction: IEEE 39 bus 10 machine demo is now really accessible
  • Removal of iteration printouts by default in offline mode. op_ssn_print_iteration_info variable must be set in workspace now.
  • HELP available for iMOV, TSB 2-level, TSB 3-level and other blocks
  • SSN Dynamic load demo available. More stable than the injection-based dynamic load of SPS. (beta version)
  • New RT-LAB and ARTEMiS SSN Monte-Carlo test demo using the snapshot feature