AC-to-DC Rectifier LAB 2 - Panel

When starting the demo, the panel in figure 15 appears first with the default settings.



Figure 15: Start-Up Panel of the Three-Phase Diode Bridge Rectifier Laboratory

For operation of the three-phase diode bridge rectifier panel, the student can refer to the panel operation of the single-phase diode bridge rectifier, because the panels of both models are very similar.
The differences in the content of scopes are presented in table 9 below.

Scope

Content of Scopes & Displayed Waveforms

Scope11

Load and AC Source voltages

Scope21

Diode D1 Voltage

Scope12

Load and AC Source currents

Scope22

Diode D1 Current

Table 9: Content of Scopes and Displayed Waveforms in Three-Phase Diode-based Rectifier


Note

The “Save File” under Scope Parameters allows the student to give different file names for data acquisition.
It is possible to save up to eleven .mat files with the name “FileSavedcurrents_X (where X can be anywhere from 0 to 10).
The student can give X values via the “Save File”, and press “Data Acq.” for acquiring data.
The data acquired can be used for offline harmonic studies.
The saved data are in the following folder:

C:\OPAL-RT\TestDrive\v2.9.0.16\Models\Package2_2_CPU\package2_1_cpu_sm_master\OpNTtarget

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323