Pos-seq, variable frequency
The Pos-seq, variable frequency component computes the positive-sequence (magnitude and phase) of the input signal abc over a running window of one cycle of the fundamental frequency given by input f. The reference frame required for the computation is given by input wt.
The output is held constant to the specified Initial magnitude and Initial phase values for one cycle of the specified initial frequency.
Symbol
Mask Parameters
Name | Description | Unit | Variable = {Possible Values} | |
---|---|---|---|---|
Description | Use this field to add all kinds of information about the component | Description = {'string'} | ||
Initial frequency | Initial frequency for the first simulation cycle. This value cannot be modified during the simulation | Hz | Finit = { [0, 1e12] } | |
Minimum frequency | Minimum expected frequency of the input signal. This value cannot be modified during the simulation | Hz | Fmin = { [0, 1e12] } | |
Initial magnitude | Initial value of the magnitude of the output signal for the first simulation cycle. This value cannot be modified during the simulation | MagInit = { [0, 1e12] } | ||
Initial phase | Initial value of the phase of the output signal for the first simulation cycle. This value cannot be modified during the simulation | deg. | PhaseInit = { [0, 360] } |
Input/Output Signals
Name | Description | Type |
---|---|---|
abc | Vectorized signal that can contain phase-to-ground voltages (Va, Vb and Vc) or phase-to-ground currents (Ia, Ib and Ic) | Input |
f | Frequency signal used to calculate the positive-sequence of the input signal abc | Input |
wt | Angle of the reference signal used for the calculation of the positive-sequence of the input signal abc | Input |
Mag | Signal containing the amplitude of the positive-sequence of the input signal abc | Output |
Pha | Signal containing the phase of the positive-sequence of the input signal abc | Output |
Sensor Descriptions
Name | Description | Unit |
---|---|---|
abc[a] | Signal that may contain the voltage or current of phase A | V or A |
abc[b] | Signal that may contain the voltage or current of phase B | V or A |
abc[c] | Signal that may contain the voltage or current of phase C | V or A |
f | Frequency signal used to calculate the positive-sequence of the abc input signal | Hz |
wt | Angle of the reference signal used for the calculation of the positive-sequence of the input signal abc | (rad/s) |
Mag | Signal containing the amplitude of the positive-sequence of the input signal | V or A |
Pha | Signal containing the phase of the positive-sequence of the input signal | deg |