Sequence analyzer

The Sequence analyzer component outputs the magnitude and phase of the zero-sequence (0), the positive-sequence (1) and the negative-sequence  (2) of a set of three balanced or unbalanced signals. Input signal can be a three phase voltage or current.

Symbol

Mask Parameters

NameDescriptionUnitVariable = {Possible Values}
DescriptionUse this field to add all kinds of information about the component
Description = {'string'}
Fundamental frequencyFundamental frequency used for the calculation of the magnitude and phase of the zero-sequence (0), the positive-sequence (1) and the negative-sequence  (2). This value cannot be modified during the simulationHzFnom = { [0, 1e12] }

Input/Output Signals

Name

Description

Type

abc

Vectorized signal that can contain phase-to-ground voltages (Va, Vb and Vc) or phase-to-ground currents (Ia, Ib and Ic)

Input

Mag120

Vectorized signal containing the amplitude of the zero-sequence, positive-sequence and negative-sequence component of the input signal

Output

Pha120

Vectorized signal containing the phase of the zero-sequence, positive-sequence and negative-sequence component of the input signal

Output

Sensor Descriptions

Name

Description

Unit

abc[a]

Signal that may contain the voltage or current of phase A

V or A

abc[b]

Signal that may contain the voltage or current of phase B

V or A

abc[c]

Signal that may contain the voltage or current of phase C

V or A

Mag120[Mag0]

Signal containing the amplitude of the zero-sequence component of the input signal

V or A

Mag120[Mag1]

Signal containing the amplitude of the positive-sequence of the input signal

V or A

Mag120[Mag2]

Signal containing the amplitude of the negative-sequence component of the input signal

V or A

Pha120[Mag0]

Signal containing the phase of the zero-sequence component of the input signal

deg

Pha120[Mag1]

Signal containing the phase of the positive-sequence of the input signal

deg

Pha120[Mag2]

Signal containing the phase of the negative-sequence of the input signal

deg

Internal Circuit of the Component


Example Model

This example shows the use of the Sequence analyzer block to compute the three sequence components of a three-phase unbalanced signal.