Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Generic Boiler | Programmable Parameters

boiler_on Selection of boiler operation. (On=Normal operation; Off=no boiler, constant pressure)
boiler_mod Selection of boiler model. (Internal
ch_press Boiler pressure output reference (pu)
ch_bmax Upper limit of boiler pressure (pu)
ch_kpc Proportional gain of boiler regulator (pu)
ch_ki Integral gain of boiler regulator (pu)
ch_k2 Load loss coefficient (pu)
ch_k3 Heat capacity coefficient (pu)
ch_k4 High pressure effect (pu)
ch_t8 Boiler constant (s)
ch_t9 Boiler setting constant (s)
ch_td Boiler delay setting (s).

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323