Generic Boiler | Programmable Parameters

boiler_on Selection of boiler operation. (On=Normal operation; Off=no boiler, constant pressure)
boiler_mod Selection of boiler model. (Internal
ch_press Boiler pressure output reference (pu)
ch_bmax Upper limit of boiler pressure (pu)
ch_kpc Proportional gain of boiler regulator (pu)
ch_ki Integral gain of boiler regulator (pu)
ch_k2 Load loss coefficient (pu)
ch_k3 Heat capacity coefficient (pu)
ch_k4 High pressure effect (pu)
ch_t8 Boiler constant (s)
ch_t9 Boiler setting constant (s)
ch_td Boiler delay setting (s).