boiler_on | Selection of boiler operation. (On=Normal operation; Off=no boiler, constant pressure) |
---|---|
boiler_mod | Selection of boiler model. (Internal |
ch_press | Boiler pressure output reference (pu) |
ch_bmax | Upper limit of boiler pressure (pu) |
ch_kpc | Proportional gain of boiler regulator (pu) |
ch_ki | Integral gain of boiler regulator (pu) |
ch_k2 | Load loss coefficient (pu) |
ch_k3 | Heat capacity coefficient (pu) |
ch_k4 | High pressure effect (pu) |
ch_t8 | Boiler constant (s) |
ch_t9 | Boiler setting constant (s) |
ch_td | Boiler delay setting (s). |