Benchmarks | 110-Bus 500 kV Transmission System
Model name | 110-bus 500 kV transmission system |
---|---|
Highlights |
HYPERSIM automatically parallelizes the network into 268 tasks and distributes them on all available cores for maximum speed, e.g. 10 us on 7 cores |
Model diagram | |
Single-phase nodes | 336 |
Generators (3φ, synchronous) | 14 |
Transformers (3φ) | 14 |
Single-circuit lines (3φ, Bergeron model) | 171 |
RLC (3φ) | 44 |
Breakers (3φ) and faults (4φ) | 2 + 1 = 3 |
Hardware | OP5707XG
|
Software |
|
Minimum license required | HXG Max (2 cores) |
Results 1 core |
|
Results 2 cores |
|
Results 7 cores |
* Performance under transient conditions varying considerably depending on the study type, this benchmark measures the minimum achievable time-step without overruns in steady-state conditions. A rule of thumb is to consider 10 to 20 % buffer time for calculations under transient conditions. |
Benchmark | |
Performance comparison between new (OP5707XG) and previous (OP5700) hardware generations | |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323