OP8930 Pin Assignment


Before designing cables, OPAL-RT recommends using these guidelines: Simulator EMC cable recommendations.

J1/J2 HDB44 Connector Pinout

As explained in OP8930 Hardware Interface, both HDB44 connectors J1 and J2 share the same pin-out.  The 16 analog I/O signals are routed to both J1 and J2 connectors. This allows, for example, splitting the input and output signals into two different cables.

8930

Pin

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Signal Name

A0+

A1+

A2+

GND

A4+

A5+

A6+

GND

A8+

A9+

A10+

GND

A12+

A13+

A14+

Pin

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

Signal Name

A0-

A1-

A2-

GND

A4-

A5-

A6-

GND

A8-

A9-

A10-

GND

A12-

A13-

A14-

 

Pin

31

32

33

34

35

36

37

38

39

40

41

42

43

44

 

Signal Name

A3-

A3+

GND

GND

A7-

A7+

GND

GND

A11-

A11+

GND

GND

A15-

A15+

 


The direction of the signals A0 to A15 depend on the OP8930 assembly selected :


Part NumberDescriptionAnalog In

Analog Out

OP8931** REPLACED BY OP8934 *** 16 Aout differential from single ended input SLSC Conditioning Board
A0-A15
OP893216 Ain differential to single ended SLSC Conditioning BoardA0-A15
OP8933** REPLACED BY OP8935 *** 8 Ain/8 Aout SLSC Conditioning BoardA0-A7

A8-A15

OP893416 Aout differential from single ended input SLSC Conditioning Board
A0-A15
OP89358 Ain/8 Aout SLSC Conditioning BoardA0-A7

A8-A15

J3

GNDGND
VBus_AVBus_B

XJ2 connector pinout


XJ2 SignalOP8930XJ2 PinXJ2 SignalOP8930XJ2 Pin
P0.0A0a1P2.0A8a7
P0.1GNDb1P2.1GNDb7
P0.2A1d1P2.2A9d7
P0.3GNDe1P2.3GNDe7
P0.4A2a2P2.4A10a8
P0.5GNDb2P2.5GNDb8
P0.6A3d2P2.6A11d8
P0.7GNDe2P2.7GNDe8
GNDGNDa3GNDGNDa9
GNDGNDb3GNDGNDb9
GNDGNDc3GNDGNDc9
GNDGNDd3GNDGNDd9
GNDGNDe3GNDGNDe9
P1.0A4a4P3.0A12a10
P1.1GNDb4P3.1GNDb10
P1.2A5d4P3.2A13d10
P1.3GNDe4P3.3GNDe10
P1.4A6a5P3.4A14a11
P1.5GNDb5P3.5GNDb11
P1.6A7d5P3.6A15d11
P1.7GNDe5P3.7GNDe11
GNDGNDa6GNDGNDa20
GNDGNDb6GNDGNDb20
GNDGNDc6GNDGNDc20
GNDGNDd6GNDGNDd20
GNDGNDe6GNDGNDe20
GNDGNDa17GNDGNDa23
GNDGNDb17GNDGNDb23
GNDGNDc17GNDGNDc23
GNDGNDd17GNDGNDd23
GNDGNDe17GNDGNDe23

XJ3 connector pinout


XJ3 connector

Molex connector (on standard RTI) 

XJ3 pinOP8910
HVBus_A
GGND
FVBus_B
EGND
DVUser_1
CGND
BVUser_2
AGND

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323