Trigger output

Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Trigger output

This feature outputs a synchronization signal on the TRIG OUT BNC that is available on the front panel of the Base Module. It is used to synchronize a capture device such as an oscilloscope or a logic analyzer.

It can generate a trigger pulse, 200 ns long, based on either the model synchronization, the high-resolution signal or a specified value of the engine position.

Three controls are made available to the user in the Base Module run-time panel:

  • Trig. mode: allow the user to specify which signal to output at the BNC connector. Supported values are:

Value

Description

Value

Description

0

Output a pulse at a specific engine position specified by Trig. Output value.

1

Output the model synchronization signal

2*

Output the high-resolution signal (Hi RES) produces by the RPG module

3*

Output the RESET signal of the RPG module

* Modes 2 and 3 are not yet supported

  • Trig. output: specify the angular position (expressed as a high-resolution count, .i.e. 5000 for 500° at 0.1 resolution) at which the trigger output produces the pulse. Compatible only with trigger mode = 0.
    Trig. enable: activate the trigger output (1), or disable it (0).

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323