Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Trigger output

This feature outputs a synchronization signal on the TRIG OUT BNC that is available on the front panel of the Base Module. It is used to synchronize a capture device such as an oscilloscope or a logic analyzer.

It can generate a trigger pulse, 200 ns long, based on either the model synchronization, the high-resolution signal or a specified value of the engine position.

Three controls are made available to the user in the Base Module run-time panel:

  • Trig. mode: allow the user to specify which signal to output at the BNC connector. Supported values are:

Value

Description

Value

Description

0

Output a pulse at a specific engine position specified by Trig. Output value.

1

Output the model synchronization signal

2*

Output the high-resolution signal (Hi RES) produces by the RPG module

3*

Output the RESET signal of the RPG module

* Modes 2 and 3 are not yet supported

  • Trig. output: specify the angular position (expressed as a high-resolution count, .i.e. 5000 for 500° at 0.1 resolution) at which the trigger output produces the pulse. Compatible only with trigger mode = 0.
    Trig. enable: activate the trigger output (1), or disable it (0).

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323