Documentation Home Page ◇ Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OP8930 Specification
Page Contents
- 1 General
- 2 Characteristics
- 2.1 General
- 2.2 Analog Inputs
- 2.3 Analog Outputs
- 3 Environmental
General
Product Name | OP8930 |
Part Numbers | |
Board Type | Analog input/output conditioning |
Form Factor | |
SLSC Module Design Specifications | Version 1.2.1 |
SLSC Compliance Level | OP8931/OP8932/OP8934: 1 |
Rear I/O Compatibility | OP8931/OP8934: [02] (Up to 16 output differential channels) |
Hot-Plug support | No |
Characteristics
| PCB Rev. 1 | PCB Rev. 2 |
General |
|
|
Number of channels | 16 input or output channels Number of input /outputs depend on assembly selected. See OP8930 configurations options | 16 input or output channels Number of input/outputs depend on assembly selected. See OP8930 configurations options |
Max peak current with FIU | ||
Analog Inputs | ||
Voltage Range | From unit under test: ±10V or ±30V differential (fix range) | From unit under test: ±10V or ±30V differential (software selectable) To PXI chassis: ±10V single-ended |
Exact transfer function | ±10V: Vo = 1.0015 • Vi, ±0.8% ±30V: Vo = 0.3338 • Vi, ±0.8% | ±10V: Vo = 1.0091 • Vi, ±0.6% ±30V: Vo = 0.3364 • Vi, ±0.8% |
Bandwidth (-3dB) | 500 kHz | 250 kHz |
Differential Input Impedance | 1 MΩ | 1 MΩ |
Voltage Protection | 100 V | 100 V |
Analog Outputs |
|
|
Voltage Range | From PXI chassis: ±10V single-ended | From PXI chassis: ±10V single-ended |
Exact transfer function | ±20V: Vo = 2.000 • Vi, ±0.2% | ±20V: Vo = 2.004 • Vi, ±0.2% |
Maximum current | ±50mA/channel, 250 mA/board | ±50mA/channel, 250 mA/board |
Bandwidth (-3dB) | 500 kHz | 250 kHz |
Output Impedance | 25 Ohms | <2 Ohms |
Voltage Protection | 50 VDC and 50 VAC | 60 VDC and 60 VAC |
Short-circuit Protection (continuous) | 150 mA max | 150 mA max |
Environmental
Module operating temperature | 0 °C to 85 °C |
Storage temperature | -40 °C to 85 °C |
Operating humidity | 10% to 90% non-condensing |
Storage humidity | 5% to 95% non-condensing |
Pollution Degree | 2 |
Maximum altitude | 2,000 m |
Power requirement | OP8931/OP8934: 25 W OP8932: 10 W OP8933/OP8935: 18 W |
Intended use | The OP8930 is designed for indoor use only. |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter