Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Switch parameters

Internal on resistance (Ron)

The diode internal on resistance, in ohms (Ω).

Internal off Resistance (Roff)

The diode internal off resistance, in ohms (Ω).

Switching method (Sm)

The model used to simulate the switch. There are two options:

  • Pejovic;

  • Quasi-supra (only available for eHS Gen5).

See How to choose switch model (Pejovic and Quasi-supra) for instructions on how to choose between these options.

Gate control signal (g)

The signal to control on/off state of the switch.

Discrete-time switch conductance (Gs)

The discrete-time switch conductance, in S.

See How to tune discrete-time switch condutance for detailed explanation.

Relaxation (Relax)

The relaxation parameter of the switch. Values can range between 0.1 for maximum performance or 10 for maximum stability.

See How to tune single switch parameters for detailed explanation.

Damping resistance (Rdamp)

Damping resistance value, in ohms (Ω).

See How to tune single switch parameters for detailed explanation.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323