Functions of Display Blocks
Vmmc Display Block
Vmmc Display block is shown in the figure below. It is used to display the mmc output voltage (Vmmc) of each arm. They are in p.u. value based on the nominal Vcap and updated every CPU time step. For example, if every cell capacitor voltage is 95% of the nominal value and there are 100 cells are ON, the Vmmc output is 100*.95=95.
Vcap and Vref Display
Vmmc Average Display block is shown in the figure below. It is used to display the average value of Vmmc.
Monitoring Block
Monitoring block is shown in the figure below. It is used to display more information that selected in the scope tab in MMC Parameters block.