Documentation Home Page MMC Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Functions of Display Blocks

Vmmc Display Block

Vmmc Display block is shown in the figure below. It is used to display the mmc output voltage (Vmmc) of each arm. They are in p.u. value based on the nominal Vcap and updated every CPU time step. For example, if every cell capacitor voltage is 95% of the nominal value and there are 100 cells are ON, the Vmmc output is 100*.95=95.

Vcap and Vref Display

Vmmc Average Display block is shown in the figure below. It is used to display the average value of Vmmc.

Monitoring Block

Monitoring block is shown in the figure below. It is used to display more information that selected in the scope tab in MMC Parameters block.


OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter