Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

RTE STATUS

Description

Contains RT-EVENTS Status information.

Usage

See Elements.

Elements

eRTE_NoError (0)

No Error.

eRTE_ExceedMax_Ev0 (1)

Maximum number of events is exceeded. The last event was falling.

eRTE_ExceedMax_Ev1 (2)

Maximum number of events is exceeded. The last event was rising.

eRTE_InvalidIndex (4)

The index vector contains values that exceed the maximum number of events.

eRTE_InvalidTimeVector (8)

Some elements of the time vector are not in chronological order.

eRTE_InvalidIC (16)

The initial condition does not match the first event state.

eRTE_ConsecutiveSameEvent (32)

There are some consecutive events of the same type. Events were removed.

eRTE_EventInThePast (64)

One or more events are in the past. Events were removed.

eRTE_MaxFrequency (128)

Frequency exceeds the maximum frequency.

eRTE_HW_InitializeError (67592)

Set by RT-LAB OpFcnMultiEventCapt block: Hardware not found.

eRTE_HW_OverrunError (66048)

Set by RT-LAB OpFcnMultiEventCapt block: FIFO overrun.

eRTE_HW_DataLostError (66560)

Set by RT-LAB OpFcnMultiEventCapt block: Data loss detected in input FIFO.

eRTE_HW_InvalidDataError (67584)

Set by RT-LAB OpFcnMultiEventCapt block: Invalid data formatting detected in input FIFO.

eRTE_HW_TSBData (69632)

Set by RT-LAB ‘OP5142 TSB In’ block: The RTE signal contains data obtained from firing pulses measurement and is intended to be connected to a TSB block.

eRTE_UndefinedError (4294967295)

Block/application specific error that does not match any of the previously defined code.

Examples

None

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323