Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
RTE Conversion OP5110-5120
Library
RT-EVENTS Signal Attributes
Block
Description
This block converts:
- Double-type signals output by the RT-LAB OP5110-5120 Event Detector block to RTE Boolean-type signals or
- RTE Boolean-type signals to double-type signals receive by the RT-LAB OP5110-5120 Event Generator block.
The RT-LAB OP5110-5120 Event Detector/Generator block makes use of the Opal-RT OP5110 or OP5120 reconfigurable digital input/output boards to read digital signals and detect the transitions that occur on these signals during one calculation step. For more information see RT-LAB documentation or contact Opal-RT Technologies support.
Mask
Parameters
Conversion Type | Specifies if the conversion is made from the OP5110-5120 Event detector block to the RTE Boolean data type, or from the RTE Boolean data type to the OP5110-5120 Event Generator block. |
---|---|
Number of OP5110-5120 Event Lines | The number of input/output OP5110-5120 lines. |
Maximum number of events | The maximum number of events or transitions that can occur during a single step. Over this number, events are ignored and not output. |
Time Unit | Select whether the time values will be specified as a ratio of the transition time over the duration of the step, or in seconds. |
Consider time factor | When this checkbox is checked, the RT-Lab time factor is applied to the time values of this block. Only available when the Time Unit is Seconds. |
Sample Time | The time interval between samples in seconds. Only available when the conversion type is OP5110-5120 Event Detector to RTE Boolean. |
Show Initial States input | When this checknox is checked, the input Initial States is added to the block. See the description of this input in the Inputs section below. Only available when the conversion type is OP5110-5120 Event Detector to RTE Boolean. |
Input
Initial States | The initial state of each input vector. Only available when the conversion type is RTE Boolean to OP5110-5120 Event Generator. |
---|---|
State Vector (Double) | The state vector output from the RT-LAB OP5110-5120 Event Detector block. Only available when the conversion type is OP5110-5120 Event Detector to RTE Boolean. |
Time Vector (Double) | The time vector output from the RT-LAB OP5110-5120 Event Detector block. Only available when the conversion type is OP5110-5120 Event Detector to RTE Boolean. |
Status (Double) | The status output from the RT-LAB OP5110-5120 Event Detector. Only available when the conversion type is OP5110-5120 Event Detector to RTE Boolean. |
Input (RTE Boolean) | RTE Boolean signal to send to the RT-LAB OP5110-5120 Event Generator. Only available when the conversion type is RTE Boolean to OP5110-5120 Event Generator. |
Output
Output (RTE Boolean) | The equivalent RTE Boolean-type signal. Only available when the conversion type is OP5110-5120 Event Detector to RTE Boolean. |
---|---|
State Vector (Double) | The state vector sent to the RT-LAB OP5110-5120 Event Generator. Only available when the conversion type is RTE Boolean to OP5110-5120 Event Generator. |
Time Vector (Double) | The time vector sent to the RT-LAB OP5110-5120 Event Generator block. Only available when the conversion type is RTE Boolean to OP5110-5120 Event Generator. |
Characteristics
Direct Feedthrough | Yes |
---|---|
Sample Time | Inherited and fixed discrete |
Work offline | Yes. |
Dimensionalized | Yes |
Example
The rte_event_detector.mdl and the rte_event_generator.mdl models shows how to connect the RTE Conversion OP5110-5120 blocks to the Opal-RT OP5110-5120 event detector and event generator blocks.
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter