Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OpNI60xE IO Trigger
Block
Mask
Description
The National InstrumentsESeries (or NI-60xE) cards feature two counter gate digital inputs that can be used as interrupt lines. This block, along with its associated Op Subsystem Trigger block, uses one of these gate inputs to trigger a Simulink subsystem. This block supports a list of NI60xEPXI and PCI compatible cards.
The subsystems connected to Op Subsystem Trigger will be called in a round robin fashion. For instance, the first interruption will trigger the first subsystem, the next one will trigger the second and so on. Once the last subsystem has been triggered, it all comes back to the first. At least one subsystem must be connected to Op Subsystem Trigger.
NOTE: A maximum of 8 Op NI60xE IO Trigger blocks can be found in a given master or slave subsystem.
Parameters
Bus Type | Select the bus type (PCI or PXI) of the target node in this list. |
---|---|
Card Type | Select the card model on this list. |
PCI index | Enter the PCI index (see definition)of the card on the PCI (or PXI) bus. |
Trigger Group Number | ID Shared between this block and its associated Op SubsystemTrigger block. |
Counter Number | Select the counter whose gate input is to be used (0 or 1). |
Trigger on | rising, falling or both edges of the gate input. |
Active during pause | Select this option to allow triggers to occur during pause. |
Inputs
This block has no inputs.
Outputs
This block has no inputs.
Characteristics and Limitations
Connector Pin Assignments
The triggering signal must be connected either to GPCTR0_GATE or GPCTR1_GATE depending on the selected counter. Refer to the connector pin assignments tables below to find out which pin assignment corresponds to your card model.
1) Cards NI-6070E (MIO-16E-1),NI-6052E, NI-6040E (MIO-16E-4), NI-6036E, NI-6035E, NI-6034E, NI-6032E, NI-6030E (MIO-16XE-10), NI-6024E,NI-6023E:
68-pin I/O
Pin | Description | Pin | Description |
---|---|---|---|
34 | ACH8 | 68 | ACH0 |
33 | ACH1 | 67 | AIGND |
32 | AIGND | 66 | ACH9 |
31 | ACH10 | 65 | ACH2 |
30 | ACH3 | 64 | AIGND |
29 | AIGND | 63 | ACH11 |
28 | ACH4 | 62 | AISENSE |
27 | AIGND | 61 | ACH12 |
26 | ACH13 | 60 | ACH5 |
25 | ACH6 | 59 | AIGND |
24 | AIGND | 58 | ACH14 |
23 | ACH15 | 57 | ACH7 |
22 | DAC0OUT | 56 | AIGND |
21 | DAC1OUT | 55 | AOGND |
20 | EXTREF | 54 | AOGND |
19 | DIO4 | 53 | DGND |
18 | DGND | 52 | DIO0 |
17 | DIO1 | 51 | DIO5 |
16 | DIO6 | 50 | DGND |
15 | DGND | 49 | DIO2 |
14 | +5V | 48 | DIO7 |
13 | DGND | 47 | DIO3 |
12 | DGND | 46 | SCANCLK |
11 | PFI0/TRIG1 | 45 | EXTSTROBE |
10 | PFI1/TRIG2 | 44 | DGND |
9 | DGND | 43 | PFI2/CONVERT |
8 | +5V | 42 | PFI3/GPCTR1_SOURCE |
7 | DGND | 41 | PFI4/GPCTR1_GATE |
6 | PFI5/UPDATE | 40 | GPCTR1_OUT |
5 | PFI6/WFTRIG | 39 | DGND |
4 | DGND | 38 | PFI7/STARTSCAN |
3 | PFI9/GPCTR0_GATE | 37 | PFI8/GPCTR0_SOURCE |
2 | GPCTR0_OUT | 36 | DGND |
1 | FREQ_OUT | 35 | DGND |
2) Cards NI-6071E, NI-6033E, NI-6031E:
100-pin I/O
Pin | Description | Pin | Description |
---|---|---|---|
1 | AIGND | 51 | ACH16 |
2 | AIGND | 52 | ACH24 |
3 | ACH0 | 53 | ACH17 |
4 | ACH8 | 54 | ACH25 |
5 | ACH1 | 55 | ACH18 |
6 | ACH9 | 56 | ACH26 |
7 | ACH2 | 57 | ACH19 |
8 | ACH10 | 58 | ACH27 |
9 | ACH3 | 59 | ACH20 |
10 | ACH11 | 60 | ACH28 |
11 | ACH4 | 61 | ACH21 |
12 | ACH12 | 62 | ACH29 |
13 | ACH5 | 63 | ACH22 |
14 | ACH13 | 64 | ACH30 |
15 | ACH6 | 65 | ACH23 |
16 | ACH14 | 66 | ACH31 |
17 | ACH7 | 67 | ACH32 |
18 | ACH15 | 68 | ACH40 |
19 | AISENSE | 69 | ACH33 |
20 | DAC0OUT | 70 | ACH41 |
21 | DAC1OUT | 71 | ACH34 |
22 | EXTREF | 72 | ACH42 |
23 | AOGND | 73 | ACH35 |
24 | DGND | 74 | ACH43 |
25 | DIO0 | 75 | AISENSE2 |
26 | DIO4 | 76 | AIGND |
27 | DIO1 | 77 | ACH36 |
28 | DIO5 | 78 | ACH44 |
29 | DIO2 | 79 | ACH37 |
30 | DIO6 | 80 | ACH45 |
31 | DIO3 | 81 | ACH38 |
32 | DIO7 | 82 | ACH46 |
33 | DGND | 83 | ACH39 |
34 | +5V | 84 | ACH47 |
35 | +5V | 85 | ACH48 |
36 | SCANCLK | 86 | ACH56 |
37 | EXTSTROBE | 87 | ACH49 |
38 | PFIO0/TRIG1 | 88 | ACH57 |
39 | PFI1/TRIG2 | 89 | ACH50 |
40 | PFI2/CONVERT | 90 | ACH58 |
41 | PFI3/GPCTR1_SOURCE | 91 | ACH51 |
42 | PFI4/GPCTR1_GATE | 92 | ACH59 |
43 | GPCTR1_OUT | 93 | ACH52 |
44 | PFI5/UPDATE | 94 | ACH60 |
45 | PFI6/WFTRIG | 95 | ACH53 |
46 | PFI7/STARTSCAN | 96 | ACH61 |
47 | PFI8/GPCTR0_SOURCE | 97 | ACH54 |
48 | PFI9/GPCTR0_GATE | 98 | ACH62 |
49 | GPCTR0_OUT | 99 | ACH55 |
50 | FREQ_OUT | 100 | ACH63 |
3) Cards NI-6025E:
100-pin I/O
Pin | Description | Pin | Description |
---|---|---|---|
1 | AIGND | 51 | PC7 |
2 | AIGND | 52 | GND |
3 | ACH0 | 53 | PC6 |
4 | ACH8 | 54 | GND |
5 | ACH1 | 55 | PC5 |
6 | ACH9 | 56 | GND |
7 | ACH2 | 57 | PC4 |
8 | ACH10 | 58 | GND |
9 | ACH3 | 59 | PC3 |
10 | ACH11 | 60 | GND |
11 | ACH4 | 61 | PC2 |
12 | ACH12 | 62 | GND |
13 | ACH5 | 63 | PC1 |
14 | ACH13 | 64 | GND |
15 | ACH6 | 65 | PC0 |
16 | ACH14 | 66 | GND |
17 | ACH7 | 67 | PB7 |
18 | ACH15 | 68 | GND |
19 | AISENSE | 69 | PB6 |
20 | DAC0OUT | 70 | GND |
21 | DAC1OUT | 71 | PB5 |
22 | RESERVED | 72 | GND |
23 | AOGND | 73 | PB4 |
24 | DGND | 74 | GND |
25 | DIO0 | 75 | PB3 |
26 | DIO4 | 76 | GND |
27 | DIO1 | 77 | PB2 |
28 | DIO5 | 78 | GND |
29 | DIO2 | 79 | PB1 |
30 | DIO6 | 80 | GND |
31 | DIO3 | 81 | PB0 |
32 | DIO7 | 82 | GND |
33 | DGND | 83 | PA7 |
34 | +5V | 84 | GND |
35 | +5V | 85 | PA6 |
36 | SCANCLK | 86 | GND |
37 | EXTSTROBE | 87 | PA5 |
38 | PFIO0/TRIG1 | 88 | GND |
39 | PFI1/TRIG2 | 89 | PA4 |
40 | PFI2/CONVERT | 90 | GND |
41 | PFI3/GPCTR1_SOURCE | 91 | PA3 |
42 | PFI4/GPCTR1_GATE | 92 | GND |
43 | GPCTR1_OUT | 93 | PA2 |
44 | PFI5/UPDATE | 94 | GND |
45 | PFI6/WFTRIG | 95 | PA1 |
46 | PFI7/STARTSCAN | 96 | GND |
47 | PFI8/GPCTR0_SOURCE | 97 | PA0 |
48 | PFI9/GPCTR0_GATE | 98 | GND |
49 | GPCTR0_OUT | 99 | +5V |
50 | FREQ_OUT | 100 | GND |
Direct Feedthrough | No |
---|---|
Discrete sample time | No |
XHP support | No |
Work offline | No |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter