Documentation Home Page OPAL-RT Schematic Editor Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Breaker

This component device allows current to flow in both directions and can also block voltage in both directions. Its states depends on gate control signal (controlled commutation) and on the conditions imposed by the external circuit: the transition from conduction to blocking state only occurs when the current is null.

Parameters

Internal resistance (Ron)

The diode internal on resistance, in ohms (Ω).

Internal off resistance (Roff)

The diode internal off resistance, in ohms (Ω).

Gate control signal (g)

The signal to control on/off state of the switch.

Discrete-time switch conductance (Gs)

The discrete-time switch conductance, in S.

See How to tune discrete-time switch condutance for detailed explanation.

Relaxation (Relax)

The relaxation parameter of the switch. Values can range between 0.1 for maximum performance or 10 for maximum stability.

See How to tune single switch parameters for detailed explanation.

Damping resistance (Rdamp)

Damping resistance value, in ohms (Ω).

See How to tune single switch parameters for detailed explanation.

Electrical Ports

  • From top to bottom, the electrical ports are the positive and negative ports of the source respectively named p1 and n1

Inputs

g

Digital input controlling the gate. This input could be assigned to a digital input channel or a signal coming from Simulink or HYPERSIM.

Characteristics

Advanced - Gen 4

Advanced parameters for Gen 4 solver architecture:

  • Discrete-time switch conductance (Gs)

are only visible when selecting Nodal Analysis (Gen4) circuit analysis method in Solver Settings.

Precision on how to tune this parameter can be found here: https://opal-rt.atlassian.net/wiki/spaces/FPET/pages/22924052.

Advanced - Gen 5

Advanced parameters for Gen 5 solver architecture:

  • Relaxation (Relax)

  • Damping resistance (Rdamp)

are only visible when selecting State-space Analysis (Gen5) circuit analysis method in Solver Settings.

Precision on how to tune those parameters can be found here: https://opal-rt.atlassian.net/wiki/spaces/FPET/pages/250380336.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323