Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
RTE-Drive ABC-DQ
Library
RTE-Drive Measurements
Block
Description
The RTE-Drive ABC-DQ block performs the abc to dq transformation on a set of three-phase signals. It computes the direct axis Vd and quadratic axis Vq quantities in a two-axis rotating reference frame according to the following transformation:
Vd = [ cos(θ) * (2*Vab+Vbc) + sqrt(3) * Vbc *sin(θ)] / 3
Vq = [ sin(θ) * (2*Vab+Vbc) - sqrt(3) * Vbc *cos(θ)] / 3
The transformation is the same for the case of a three-phase current; you simply replace the Va, Vb, Vc, Vd and Vq variables with the Ia, Ib, Ic, Id, and Iq variables.
Mask
Parameters
N/A.
Input
abc (RTE Double) | Three phases of input voltages (or currents). |
---|---|
θ (Double) | Rotating reference phase θ. |
Output
sin, cos (Double) | Sine and cosine of the rotating reference phase. |
---|---|
q,d (Double) | q and d voltage (or current) components. |
Characteristics
Direct Feedthrough | Yes |
---|---|
Sample Time | Inherited and fixed discrete. |
Work Offline | Yes |
Dimensionalized | Yes |
Example
N/A.