Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

RT-LAB | Release Notes 2023.3

Page Content


RT-LAB 2023.3.2

Software Toolboxes Installed with RT-LAB

Toolbox

Version

Toolbox

Version

ARTEMiS

7.7.5

Phasor-Domain Simulation (ePHASORSIM)

2023.3

FPGA-Based Simulation (eHS)

2.15

RT-EVENTS

4.7.5

RT-XSG

3.4.0

MMC

2.10

I/O Interfaces

OPAL-RT Board

  • Fixed greyed out directions in DIO for OP5369

  • Fixed simulation not resetting due to incorrect chassis ID

FPGA-Based Simulation

  • Added the support of x32 and x64 licence class for eHS Gen5

  • Added the support of new eHS solver reset pin in the Schematic Editor Workflow

  • Added the support of low latency solver strategy for eHS Gen5

RT-XSG

  • Added the support of Xilinx Vivado 2022.2

  • Added SPI slave blow allowing a different sizes of MISO and MOSI

  • Added I2C Master and Slave blocks

  • Fixed the bitbasher on the 2nd channel for Sine_in in the Resolver Input Subsection block

  • Fixed unresolved links in OP5367 IO Block library

  • Removal of Xilinx Vivado 2017.X

  • Removal of Matlab R2016a/R2016b

  • Removed support for OP4200

RT-LAB 2023.3.1

I/O Interfaces

OPAL-RT Board

  • Fixed issue when enumerating multiple FPGAs

FPGAScope

  • Fixed issue with FPGAScope on Redhat systems

RT-LAB 2023.3.0

Software Toolboxes Installed with RT-LAB

Toolbox

Version

Toolbox

Version

ARTEMiS

7.7.5

Phasor-Domain Simulation (ePHASORSIM)

2023.3

FPGA-Based Simulation (eHS)

2.14

RT-EVENTS

4.7.5

RT-XSG

3.3.6

MMC

2.10

Added

  • Dashboards: Added support for graph widgets

  • Dashboards: Added dashboard rtdemo1 example model

  • Added support for Windows 11

  • Added Exata example model

  • Added a notification in the model compilation log to inform the user that support for Matlab 2020A and 2020B will be removed from the upcoming RT-LAB 2024.1

Improved

  • Improved the display of the warnings during model compilation by adding an environment variable SHOW_COMPILER_COMMANDS

  • Improved the robustness of Data Definition Format (DDF) file generated by the FMUConfGenerator

  • Prevented the user from using Model Exchange FMU

  • Homogenized the Orchestra API documentation and fixed typos

  • Improved performance for AMD CPUs on Opal-RT Linux 64 bits targets

Fixed

  • Fixed issue where models were blocked when attempting to exchange data unidirectionally through Orchestra using the I/O interface

  • Removed security in FMUConfGenerator preventing the generation of unidirectional orchestra communication

  • Fixed issue related to RT-LAB version’s upgrade on target when loading several Orchestra models and framework

  • Fixed issue causing the project to close every time parameters are loaded using snapshot

  • Added functions not exported in the public Orchestra API: RTCheckReadyToGo(), RTGetSkipWaitToGoAtConnection(), RTSetSkipWaitToGoAtConnection(), RTUseFlagWithTool()

I/O Interfaces

CAN

  • Added support for the next generation of Kvaser CAN PCIe card (01414)

  • Fixed data not reaching maximum range as specified in the configuration

  • Fixed problem with bus load monitoring

TCP/UDP

  • Added support for VLAN (802.1q) management

  • Added option to change message order for custom data frames

Pickering

  • Fixed support for more than one PXI chassis

Artemis

Phasor-Domain Simulation

  • Added excel migration tool from version 1.8 to 2.0

  • Added news components imported from PowerFactory

    • ExciterAC7B

    • TurbineGovernorDEGOV

    • Bus Coupler (ElmCoup)

  • Updated Static Generator (ElmGenstat) component imported from PowerFactory

  • Fixed internalVang output pin being incorrectly named getInternalVang

RT-EVENTS

  • Fixed issue with removal of RTE-Drive blocks

MMC

  • Re-organized MMC blocks for better maintainability and easier use as described in Overview of the MMC Valves Library

  • Combined the MMC HVDC examples (CPU+HVDC) using the new MMC Valves blocks

  • Deleted obsolete DEMOS MMC4

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter