Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Data Logger File Browsing with ScopeView
The ScopeView graphic window side ribbon allows navigating through data logging files.
From left to right, the controls are as follows:
- Return to the beginning of the file
- Show the previous frame
- Go to the frame which corresponds to the parameters below
- Show the next frame
- Show the last frame
The parameters are as follows:
Start time | Start time of the frame to display. | |
Time length | Length of the frame to display. | |
Trigger type | ||
---|---|---|
None | No trigger applied. | |
Rising | Use a rising edge with the trigger value. | |
Falling | Use a falling edge with the trigger value. | |
High | Use the first value higher than the trigger value. | |
Low | Use the first value lower than the trigger value. | |
Trigger signal | Signal used by the trigger option. | |
Trigger value | Value of the trigger threshold. | |
Trigger offset | Value of the time delay applied to the trigger value. | |
Time format | Absolute : The graph will show values from Start to Start+Time length Relative : Result will be shift result on the time axis, showing values from 0 to Time length. |
Note that Trigger options in this window are independent of those set in the Data Logger Configuration. The ScopeView triggers apply to reading the file whereas the data logger triggers apply to writing the file.
The Time format option, used with the Trigger options, will help comparing signals from 2 oprecs, in case events happened at uncontrolled times during their recordings, such as the simtrig API command.
Note that the following table links the GUI Element Labels with the API call setDataPointParameter, so that users may understand how to access GUI parameters through API calls.
UI text | Api text |
---|---|
Time length | timeLength |
Trigger Type | triggerType |
Trigger signal | triggerSignal |
Trigger value | triggerValue |
Trigger offset | triggerOffset |
Time format | triggerSignal |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323