HYPERSIM
Software Toolboxes Installed with HYPERSIM
Toolbox | Version Number | |
---|---|---|
2.20.1 |
New features
A newControl Microgrid library is available, offering multiple control blocks:
External controllers can now be added to HYPERSIM based on the recommendations of the CIGRE B4.82 working group which allows to standardize the integration of real manufacturer code in simulation software.
See CIGRE Interface for more details on how to add and configure a CIGRE block to a circuit.
See The CIGRE Interface for more details on how to create a CIGRE library.
A new example model has been added to demonstrate the CIGRE block using a Forward Euler integrator: Examples | CIGRE integrator .
A new option has been added that allows to define a number of steps to be executed without IOs at the beginning of the simulation to improve simulation performance.
See the “Number of steps before enabling I/Os” option in the https://opal-rt.atlassian.net/wiki/spaces/DOCHS/pages/20189498/Simulation+Settings#Advanced .
Note that before that, HYPERSIM was always executing 100 steps without IOs. This new option simply allows to change this value.
It is now possible to get the license number and target number in the license panel of the Target Manager.
A new method
getVersion
is available to get the current HYPERSIM versionMultiple new simulation and task mapping settings can now be updated using the
setPreference
andgetPreference
methods. These settings are now listed in theSimulation Settings and the Task Manager | Summary and Preferences documentation.
Improvements
Prevent the creation of an I/O Interface with a duplicated name.
It is now possible to start/stop the recording of signals directly in the /wiki/spaces/DOCHS/pages/20176638.
Note that the control center has to be launched before the simulation has started.
Error highlight in HYPERSIM console has been improved.
An error message is now displayed when the network adapter of the localhost target is set to an invalid IP address in the Target Manager.
Note that before that, the HYPERSIM engine would simply crash.
The Target Managerlicense panel now warns when no license is installed.
The Load Flow Viewer now has a “clear all” contextual menu to clear the content of the “Output” tab.
Firmware and Hardware mismatches are now clearly stated in the simout console.
Bug fixes
Fixed an issue where the RT Monitor table was displaying incorrect status in the “Enabled” column when scrolling the table
Fixed the Start/stop timeout defined in HYPERSIM (Simulation Settings → Advanced → Simulation Server) that was not always correctly taken into account.
Fixed an issue during analyse when a UCM with selected sensors was duplicated.
Fixed an issue where the Activation Tool was not responding when applying a license from Help&Support.
Fixed an issue where the HYPERSIM engine was crashing when analyzing the network from the Load Flow Viewer.
Fixed an issue where the HYPERSIM engine would crash with certain parameter configuration of the 3-winding, w/sat + tap +dec block. The engine would crash when
the
Vmin
parameter was greater than theVmax
parameter, orthe
Vnom
parameter was not betweenVmax
andVmin
Fixed a HYPERSIM engine crash when a file that is not a .pun was used in line components.
Fixed an issue that was slowing down the load flow computation in some cases.
Fixed a bug where Load Flow properties weren't being saved when the model was saved.
Fixed an issue where the Frequency Protection block was not taking into account the initial value.
Fixed an issue where changes to parameters in the Load Flow window were not applied, despite appearing to update visually.
Fixed an issue where Line with Line generator did not take the frequency and the ground resistivity into consideration.
Removed
Unused
G_Ref
andP_Ref
sensors on Network FACTS and HVDC LCC pulse components were removed.
Signal Visualization and Processing
Dashboards
FPGAScope
Signal display order in the FPGA Scope now follows the order defined in the FSD file.
Fixed potential ScopeView crash when making an FPGA Scope acquisition with multiple FPGAs
Unified Database
PowerFactory Import
Added support of subsystems
Added support of the WEHGOV turbine governor blocks
Added support of the GAST turbine governor blocks
PSS/E Import
The following components are now imported as native HYPERSIM components
IEESGO
GGOV1
DEGOV
IEEEG1
ESAC6A
Added warning message when a model is imported without a dyr file
Improved import time performance for large models
Fixed an error in connecting the ESST1A
PSCAD Import
Fixed an issue when several
master:import
shared the same name in a given subsystemFixed missing items in the PSCAD input model intermediate library
I/O Interfaces
Allow signals to be renamed in the I/O Interface Configuration window
Improved stability by ensuring that asynchronous computation components of I/O interfaces run either on core 0 or on a dedicated core, but not on the core of the simulation itself
CAN
Added support for the CAN driver using the Kvaser PCIe card
FPGAScope
Fixed capability to differentiate boards of the same family type
Fixed crash of simulation when using an RT core
IEC 61850
Added support for sending a report to multiple MMS client instances
MODBUS Slave
Added support for TCP slave IDs up to 255
OPAL-RT Board
Added capability to program multiple OP4810-IO/OP4815-IO platforms in parallel during the load of a model
Added the display of extra information such as the IP and MAC addresses to the detection of OP4810-IO/OP4815-IO platforms
Improved workflow by keeping connections even if a raw data point's name changes
Improved workflow by skipping bitstream programming if OP4810-IO/OP4815-IO platforms are configured with an empty chassis name and/or an empty IP address
Fixed reload of bitstreams on SGI systems
Fixed bitstream configuration update mechanism to:
keep the name of raw data signals
keep the byte and bit offsets of raw data signals
keep the state of the ‘Enable FPGA scope’ check-box
support merging configurations for OP48H20 cards
Fixed filter for bitstream file browser
Fixed wrongly displayed message about firmware mismatch
Fixed wrongly found hardware mismatch for extra slot of OP4810-IO/OP4815-IO platforms
Fixed validation of threshold limits for digital channels
Synchronization
Fixed logs that were referencing the wrong network interface used by the Oregano card