Generic RLC Grounded
Mask and Parameters
The grounded generic RLC filter consists of a specific RLC combination as shown in the figure above.
Grounded filters, when used in a 3-phase system, can also have the grounding connection type configured as any of the following: Y ground, Y floating or Delta.
To specify the parameters of a filter, SI units are always used. The PU unit system is not available for all filter models.
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
This component supports 1-phase and 3-phase connections and the port is updated automatically upon connection.
Net_+: Positive network connection
Inputs
- None
Outputs
- None
Sensors
Since the filters are simulated as elements forming a whole and not as individual elements, the following signals are made available through the sensors for acquisition:
- I: Current in (A) when using in a 1-phase network
- I(a,b,c): Current in (A) for each phase when using in a 3-phase network
Hence the values of the current flowing in the individual elements are not available.