Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Generic RLC Grounded

Description

The grounded generic RLC filter is available both for 1-phase and 3-phase connections. It's also available with a series connection.


Table of Contents

Mask and Parameters

The grounded generic RLC filter consists of a specific RLC combination as shown in the figure above.

Grounded filters, when used in a 3-phase system, can also have the grounding connection type configured as any of the following: Y ground, Y floating or Delta.

To specify the parameters of a filter, SI units are always used. The PU unit system is not available for all filter models.


Ports, Inputs, Outputs and Signals Available for Monitoring

Ports

This component supports 1-phase and 3-phase connections and the port is updated automatically upon connection.

  • Net_+: Positive network connection

Inputs

  • None

Outputs

  • None

Sensors

Since the filters are simulated as elements forming a whole and not as individual elements, the following signals are made available through the sensors for acquisition:

  • I: Current in (A) when using in a 1-phase network
  • I(a,b,c): Current in (A) for each phase when using in a 3-phase network

Hence the values of the current flowing in the individual elements are not available.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323