Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
TestView
TestView is a software used to define and execute tests on models developed in HYPERSIM. One can, through a user-friendly GUI, define a script that sets the parameters of a model, executes that test, processes the signals, saves the data and re-runs that test or another one. It has moreover access to all ScopeView capabilities.
Main Features
- It supports offline and real-time simulations.
- It can repeat a test on one model (a script) any number of times.
- It can run any number of scripts (batch mode), thus making the number of tests on any number of models virtually infinite. (Any limitation usually comes from Java heap memory and how the test is defined, but TestView can easily run thousands of tests without involvement on the part of the user.)
- It can create an instance of ScopeView and has access to all ScopeView functionalities.
- It can read values from an Excel file and automatically adjust the number of tests to execute. It can also write the processing results in an Excel file.
- It has a context-based GUI; no programming skills are required.
- It has post-processing capability, meaning that it can compare the results from different tests without the user’s intervention.
- It can export data in different formats (COMTRADE, MAT, PS and TXT), as well as waveforms (JPG, PNG and PDF).
Consideration Before Importing an HYPERSIM Model to TestView
- Make sure the model current configuration uses the proper target (in Settings)
- Make sure the model is running properly on the defined target (e.g. check that the model does not diverge in ScopeView and verify that there are no 'stretched step' in RT Monitor).
- Save the sensors & I/Os using the 'save' or 'save as'.*
*Important: it is mandatory if you are using any communication protocol or analog/digital I/Os. The I/O files won't be imported correctly if the sensors are not saved prior to the import.
- TestView | GUI Walkthrough
- TestView | Commands Available for Tests
- TestView Command | HYPERSIM | HYPERSIM Test
- TestView Command | HYPERSIM | HYPERSIM Settings
- TestView Command | Main | Breaker
- TestView Command | Main | Multi-Breaker
- TestView Command | Main | Snapshot
- TestView Command | Main | Miscellaneous
- TestView Command | Main | CmdLine
- TestView Command | Main | Excel
- TestView Command | Main | GetValue
- TestView Command | Main | Processing
- TestView Command | General | Loop
- TestView Command | General | If (expression)
- TestView Command | General | Else [ if(expression) ]
- TestView Command | General | Sleep
- TestView Command | General | Pause/Message
- TestView Command | General | Macro
- TestView Command | General | Assign
- TestView Command | General | Expression
- TestView Command | General | Eval
- TestView Command | General | Input Value
- TestView Command | General | TableOut
- TestView Command | General | GraphicOut
- TestView Command | Miscellaneous | Action Group
- TestView Command | Miscellaneous | Table Report
- TestView Command | Extra | Post Sequence
- TestView Command | Extra | Node Test (Deprecated)
- TestView Command | Extra | Processing (Deprecated)
- TestView | Data Architecture
- Example 1: Changing the Timing of a Fault
- Example 2: Using Variables in TestView
- Example 3: Using Excel to Define Input Parameters
- Example 4: Executing an Existing Project (HYPERSIM <6.2)
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter