Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

C-Type Grounded

Description

The grounded C-type filter is available both for 1-phase and 3-phase connections. It's also available with a series connection.


Table of Contents

Mask and Parameters

The grounded C-type filter consists of a specific RLC combination as shown in the figure above.

Grounded filters, when used in a 3-phase system, can also have the grounding connection type configured as any of the following: Y ground, Y floating or Delta.

To specify the parameters of a filter, SI units are always used. The PU unit system is not available for all filter models.


Ports, Inputs, Outputs and Signals Available for Monitoring

Ports

This component supports 1-phase and 3-phase connections and the port is updated automatically upon connection.

  • Net_+: Positive network connection

Inputs

  • None

Outputs

  • None

Sensors

Since the filters are simulated as elements forming a whole and not as individual elements, the following signals are made available through the sensors for acquisition:

  • I: Current in (A) when using in a 1-phase network
  • I(a,b,c): Current in (A) for each phase when using in a 3-phase network

Hence the values of the current flowing in the individual elements are not available.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter