Inductance calculations

Once all winding calculations n for a specific machine are available, the various inductances can be computed according to the following formula:

where k0 and k2 are geometrical coefficients obtained from electrical parameters and intermediary inductance calculations; x in brackets is the expected value of X, p the number of pole pairs, and theta the rotor electrical angle.

The inductances can be expressed in a more convenient form:

Lyx0, Lyx1, and Lyx2 are computed before the simulation. This expression could be further reduced to a single trigonometric function with a phase term but its computational  cost in quite high for faulty machines with numerous parallel windings.


OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323