ABB PS935 | Supported Features and Limitations

Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

ABB PS935 | Supported Features and Limitations

Supported Features

  • Configurable using the GUI of HYPERSIM but also using the .io file workflow; both methods yield the same results
  • Supports 3 modes:
    • Software loopback
    • Hardware loopback
    • No loopback
  • Use of PS935 hardware can be daisy chained
    • Done by connecting the OUT PCIe port of the nth PS935 device to the IN PCIe port of the N+1th device
    • The interconnection is seamless for the OPAL simulator
    • Each PS935 device is identified by its MAC address (an 8 numeral hexadecimal value)
    • One PS935 HYPERSIM interface is necessary per PS935 device
  • Supports exchange of up to 256 floating point values per direction
  • Supports exchange of up to 512 binary values per direction

Limitations

  • The board requires to be flashed each time the OPAL-RT simulator interfacing with it it is booted
  • Flashing the firmware is only possible after a boot-up of the system i.e. cannot re-program a firmware or change it without having gone through a power-up sequence
  • Firmware is not retro-compatible, the firmware used for the PS935 device needs to be compatible with the hardware
  • If a problem occurs during the upload of the firmware, the device must be rebooted followed by rebooting the OPAL simulator before attempting the upload again

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323