Switch
On this page:
Parameters
Symbol | Description | Unit |
|---|---|---|
From Bus | The phase name of the first bus | A unique name |
To Bus | The phase name of the second bus | |
ID | Switch name (ID) | |
Status | Connect/Disconnect status |
|
Note:
When the switch is on (closed) the series resistance between the From Bus and To Bus is 1e-6 pu.
When the switch is off (open) the series resistance between the From and the To Bus is 1e6 pu The shunt admittance connected to the switch is G=1e-6 pu.
When the switch is used to isolate an unenergized portion of the network that has loads, some numerical instability in the voltage of the isolated bus is expected. However, this will not affect the energized portion of the network.
Available I/O pins
No | Pin Description | Pin Type | Value/Unit | Instruction |
|---|---|---|---|---|
1 | Switches and breakers (each phase) | I/O |
| switchID/status |
2 | Get current magnitude of a switch | O | A (RMS) | switchID/Imag |
3 | Get current angle of a switch | O | Degree | switchID/Iang |
Example
See the Switch page in phasor08_IEEE13.xlsx file in the example phasor08.