OpCanAc2 LDF SendData

Block

Mask

Description

This block is used to transmit data from Master to Slaves. It is controlled directly by LIN Scheduler Simulink block.

This block acts like an OpCanAc2 Send block with additional scheduling capabilities. These extra capabilities allow the block to receive LIN Scheduler control signals which carry the appropriate ID of LIN frame to transmit; in addition, it does the pre-scaling of the send signals according to the rules stated in LDF file used to create this block.

Parameters

Node NameThe name of the node to which the message is attached. If the LIN frame is not attached to any node, the name displayed is (Void).
MSG NameThe name of the LIN frame.
Controller IdSee OpCanAc2 Send documentation.


Inputs

DataThis input reads the data to be transmitted through the LIN network; it does the pre-scaling of the send signals according to the rules stated in LDF file used to create this block.
Req_LengthThis input receives the actual length of the corresponding LIN frame.
Scheduler_CtrlThis input is controlled by the LIN Scheduler Simulink block.


Outputs

See OpCanAc2 Send documentation.

Characteristics and Limitations

This block is an auto-generated masked subsystem and there is no rtio library associated with it.

Direct FeedthroughN/A
Discrete sample timeN/A
XHP supportYes