Documentation Home Page ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Positive Sequence Load

On this page:

This library includes three types of loads:

  • Constant impedance loads.

  • Constant power loads.

  • Constant current loads.

Constant Impedance Load

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Load name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Bus

Bus name

a unique name*

P (MW)

Active power in 1 p.u. voltage

MW

Q (MVAr)

Reactive power in 1 p.u. voltage**

MVAr

Constant Current Load

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Load name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Bus

Bus name

a unique name*

P (MW)

Active power

MW

Q (MVAr)

Reactive power**

MVAr

Constant Power Load

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Load name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Bus

Bus name

a unique name*

P (MW)

Active power

MW

Q (MVAr)

Reactive power**

MVAr

Notes:

(*) The bus name is the bus that the load is connected to. 
(**) Q value is a positive quantity for inductive loads while it is negative for capacitive loads.

Available I/O Pins

No

Pin Description

Pin Type

Value/Unit

Instruction

No

Pin Description

Pin Type

Value/Unit

Instruction

1

Set/Get service status

I/O

1: In-service

0: Out-of-service

loadID/status

2

Set active and reactive power

I

MW

MVAr

loadID/P

loadID/Q

3

Get current magnitude

O

p.u. (network base)

loadID/Imag

4

Get current angle

O

Degree

loadID/Iang

Example

See the Load page in phasor01_IEEE39.xlsx file in demo phasor01.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323