Gate Turn-Off Thyristor (GTO)
Mask and Parameters
General
Name | Description | Unit | Variable = {Possible Values} |
---|---|---|---|
Vmin | Forward voltage drop | V | {[0,1e12]} |
Ropen | Open state resistance | Ohm | {(0,1e12]} |
Rclose | Closed state resistance | Ohm | {(0,1e12]} |
Rsnubber | Snubber resistance | Ohm | {[0,1e12]} |
Csnubber | Snubber capacitance | F | {[0,1e12]} |
Control type | External Input pins: Schematic control signal; the received integer is converted to a binary string where each digit corresponds to a phase External Input sensors: Target digital inputs |
Advanced
Name | Description | Unit | Variable = {Possible Values} | |
---|---|---|---|---|
Fail reset | Fail reset | {Enable, Disable} | ||
Precision valve | Enable: Enables recalculation of the state switch command using exact time between steps (as percentage of time step) Disable: does not use precision valve | {Enable, Disable} | ||
Imin | Holding current | A | {[0,1e12]} | |
Fbov | Forward break over voltage | V | {[0,1e12]} | |
Rbov | Reverse break over voltage | V | {[0,1e12]} |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
Name | Description |
---|---|
Net_1 | Network connection |
Net_2 | Network connection |
Inputs
Name | Description |
---|---|
D | Delay used for precision valves |
P | Binary coded firing pulses |
Outputs
None
Sensors
Name | Description | Unit |
---|---|---|
D | Delay used for precision valve, measured from changing point to current time step | s |
FailSig | Fail reset signal | |
I | Diode current | A |
Delay | Delay due to forward voltage drop | s |
Delay12 | Delay in forward GTO Thyristor mode | s |
State12 | Diode state | |
P | Binary coded firing pulses | |
DelayExt12 | Delay for external trigger | s |
Cmd12 | Signal state command | |
CmdExt12 | Signal state external command |