Documentation Home Page ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Spot Load and Distributed Load Data

Entry

Description

Acceptable values

Entry

Description

Acceptable values

Number (in ‘Spot Load’ box)

Load identifier

Any alpha-numerical string or num­bers.

Status (in ‘Spot Load’ box)

Connection status of the load

Connected

Phase

Phase present in the network

Any selection on the combination of A, B and C

Customer Type (in ‘Settings’ box)

Load type

Constant Power load, Constant Cur­rent load, Constant Impedance load or the combination of the above three types of load defined in Volt­age Sensitivity Load Model box in Customer types editor.

Configuration (in ‘Settings’ box)

Load configuration

Star connection to ground, Delta connection.

Format (in ‘Settings’ box)

Load input format

(kW & kVAr) or (kVA & PF) or (kW & PF)

Real Power (A) (in ‘Settings’ box)

Phase-A Active power in kW

Any value

Real Power (B) (in ‘Settings’ box)

Phase-B Active power in kW

Real Power (C) (in ‘Settings’ box)

Phase-C Active power in kW

Reactive Power (A) (in ‘Settings’ box)

Phase-A Reactive Power in kVAr

Reactive Power (B) (in ‘Settings’ box)

Phase-B Reactive Power in kVAr

Reactive Power (C) (in ‘Settings’ box)

Phase-C Reactive Power in kVAr

Represent loads as constant impedance when voltage is smaller than the input percentage of nominal voltage. (in ‘Con­stant Impedance Voltage Threshold’ box)

Represent loads as constant imped­ance when the voltage is lower than the threshold.

0-100%

 

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter