Documentation Home Page ◇ ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Positive Sequence Shunt
On this page:
The positive sequence shunt is used in the positive sequence network.
Parameters
Symbol | Description | Unit |
---|---|---|
ID | Source name | a unique name |
Status | Connect/Disconnect status | Initial value 1 (0 for disconnected) |
Bus | Name of the bus its connected to | a unique name |
P (MW) | Active power | MW |
Q (MVAr) | Reactive power | MVAr |
Available I/O Pins
No | Pin Description | Pin Type | Value/Unit | Instruction |
---|---|---|---|---|
1 | Get current magnitude of shunt | O | A (RMS) | shuntID/Imag |
2 | Get current angle of shun | O | Degree | shuntID/Iang |
3 | Set/Get powers of shunt (profile) | I/O | kW kVAr | shuntID/P shuntID/Q |
4 | Set/Get status of shun | I/O | 0: Disconnected 1: Connected | shuntID/status |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323