Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Controlled I Source, 3-ph

Description

Controlled I Source, 3-ph

The controlled  current sources, 3-ph represent a three-phase A.C. source with a series or parallel RLC impedance. In the network, these sources only generate the signal received on the control connectors. Hence, this process serves only to amplify or inject a signal in the network.

Table of Contents

Current sources have parallel impedance only that can be series of parallel RLC elements. 

Current sources inject current between buses without grounding.

Mask and Parameters

NameDescriptionUnit

RLC connection type 

Series (series R, L, C) or parallel (parallel R, L, C)-

R

Resistance value in ohmsohms

L

Inductance value in henry.H

C

Capacitor value in faradF

Ports, Inputs, Outputs and Signals Available for Monitoring

Ports

  • The current source injects a current from one bus (port) to another (port), without grounding. 

Inputs

  • I input (current source): The current amplitude signal. three-phase signal 

Outputs

  • None

Sensors

  • I(a, b, c)_label: Current signal (current source) (A).

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323