AC V Source
Mask and Parameters
- General tab
SI or pu units:
- SI: Specifies the values of the RLC elements, voltage, current or frequency in international units (ohm, henry, farad, volt, ampere and hertz);
- pu: Specifies the values of the RLC elements, voltage, current or frequency in pu;
Name | Description | Unit |
---|---|---|
Starting mode (Slow/Fast) | If “Fast”, the source is immediately activated or deactivated. If “Slow”, when the source is activated, the amplitude of the source increases linearly from zero to the steady-state value. When the source is deactivate, the amplitude of the source decreases linearly from the steady-state value to zero. | - |
RLC type | Series (series R, L, C) or parallel (parallel R, L, C) | - |
Phase sequence |
| |
Base Power (total) | Base power for three phase | MVA |
Base voltage (rmsLN) | Base voltage phase to ground | kV |
Base Frequency | Base frequency | Hz |
Amplitude (peak) | Peak value of the amplitude for the source voltage in volts (or pu) for each phase | volts (or pu) |
Angle | Angle of each phase in degrees. The value of the angles can be modified either by directly entering the numerical values in the appropriate fields or by adjusting the hands on the dial. | degrees |
R | Resistance value in ohms | ohms (or pu) |
L | Inductance value | henry (or pu) |
C | Capacitor value | farad (or pu) |
These parameters can be used for the steady-state solution of the network.
Name | Description | Unit |
---|---|---|
Type |
| |
Voltage | Pu voltage, specified for PV-bus and Slack-bus, calculated for PQ-bus. | pu |
Angle | Phase angle of voltage, specified for Slack-bus, calculated for PQ-bus and PV-bus. | degrees |
Q minimum limit | Minimum reactive power generation limit for PV-bus | Mvar |
Q maximum limit | Maximum reactive power generation limit for PV-bus | Mvar |
P | Specified generation for PV-bus and Slack-bus, specified load for PQ-bus | Mw |
Q | Specified load for PQ-bus, calculated within limits for PV-bus, calculated for Slack-bus. | Mvar |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
- The voltage source has only one network connector (port), since is always referenced to the ground.
Inputs
- None
Outputs
- None
Sensors
At acquisition, the following signals are made available by the sensors:
• I : Measured current (voltage source) (A).
• VINT : Source voltage signal (V).