Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
EMTP | List of Partially Compatible Components
This section presents the list of components from the EMTP libraries that are partially supported when the EMTP models are loaded in HYPERSIM. These blocks are compatible with an HYPERSYM simulation. However, some of their options are not supported in HYPERSIM. The first column indicates the name of the block in EMTP while the second column indicates the equivalent name of the component in HYPERSIM. The third column lists the options that are not supported in HYPERSIM.
Control
Component in EMTP | Name in HYPERSIM | Incompatibility |
delay | delay | Arbitrary pulse delay mode not supported |
derivative | derivative | End-step du/dt, and Mid-step d2u/dt2 modes not supported |
table function | Floating-point constant | The maximum number of rows supported is 500 |
Lines
Component in EMTP | Name in HYPERSIM | Incompatibility |
CP line/cable m-phase | Constant param, m-ph | HS models only support 1, 2, 3, 4, 6, 9, and 12 phases |
Loads
Component in EMTP | Name in HYPERSIM | Incompatibility |
PQ load with load-flow | PQ load with load-flow | Negative Power value not supported. Power will be set to 0. Visible ground pin not supported. |
Machines
Component in EMTP | Name in HYPERSIM | Incompatibility |
Asynchronous | Induction motor with cage rotor | Steady-state initialization and total saturation are not supported. Saturation data in D-axis is limited to 10 points. Saturation data in Q-axis is not considered in HYPERSIM. Deep bar factor not supported. Lock rotor shaft for negative speed is not supported. Absolute speed damping is not supported. HYPERSIM supports only WYE grounded connection for the armature winding. Rotor speed control is not supported. The Multi-masses model is not supported. Mechanical torque in pu control is not supported. |
Synchronous | Synchronous machine | HYPERSIM uses EL 1.0 and EU 1.2 for saturation in D-axis. Sgu is smaller than Sgl. Values swapped. Saturation data in Q-axis is not considered in HYPERSIM. HYPERSIM does not support Canay impedance in extra data. HYPERSIM only represents 1 damper in the D axis. HYPERSIM only supports 2 dampers in the Q axis. HYPERSIM support only WYE grounded connection for the armature winding. HYPERSIM supports only open circuit data (D Axis). HYPERSIM supports only open circuit data (Q Axis). The Multi-masses model is not supported. |
Meters
Component in EMTP | Name in HYPERSIM | Incompatibility |
Control signal meter | Control signal meter | RMS meter not supported |
Current scope and observe | I measurement, 1ph | v and p observables not supported |
Simulation probe | Simulation probe | Simulation stop time and Base Frequency not supported |
Nonlinear
Component in EMTP | Name in HYPERSIM | Incompatibility |
L nonlinear | Series nonlinear L | Negative values are not supported |
ZnO | Series nonlinear R | HYPERSIM supports a maximum of 10 exponential segments. v, p, e observables not supported. Exponential segments after flashover not supported |
RLC branches
Component in EMTP | Name in HYPERSIM | Incompatibility |
PI | PI | Single-phase line not supported |
PI small | PI small | Single-phase line not supported |
Sources
Component in EMTP | Name in HYPERSIM | Incompatibility |
AC current source | AC current source | Unsupported start and stop time |
AC voltage source | AC voltage source | Serial voltage source not supported. Unsupported start and stop time |
AC voltage source (3-ph) | AC V source | Unsupported start and stop time |
AC voltage source and impedance | AC voltage source and impedance | Unsupported connections to pink Visible ground pin not supported Unsupported start and stop time |
Controlled current source | Controlled I source, 1-ph | Unsupported start and stop time |
Controlled voltage source | Controlled V source, 1-ph | Unsupported start and stop time |
Load-Flow Bus | Load-Flow equivalent | HYPERSIM only supports Positive Sequence R impedance HYPERSIM only supports Positive Sequence L impedance Remote control bus not supported R must be entered as Sequence Data L must be entered as Sequence Data |
Switches
Component in EMTP | Name in HYPERSIM | Incompatibility |
Controlled switch | Controlled switch | v and p observables not supported |
Diode (ideal) | Diode | Closed at T0 not supported |
Ideal switch | Circuit breaker, 1-ph | v and p observables not supported |
Ideal switch : Breaker Symbol | Circuit breaker, 1-ph | v and p observables not supported |
Thyristor (ideal) | Thyristor (ideal) | v and p observables not supported Closed at T0 not supported |
Transformers
Component in EMTP | Name in HYPERSIM | Incompatibility |
ideal unit m-windings | ideal unit m-windings | HYPERSIM only support one secondary winding with a controlled ratio HYPERSIM only supports a maximum of two secondary windings |
Three-phase nameplate input | 2 winding | HYPERSIM doesn't support R1 <= 0, using R1 = 1E-6 L1 < 1E-6 pu, using L1 = 1E-6 pu R2 <= 0, using R2 = 1E-6 L2 < 1E-6 pu, using L2 = 1E-6 pu Using Rm and Lm = 30000 pu for linear transformer Primary and secondary neutral impedance values must be entered manually. Exported mask not supported |
YgYgD nameplate input O | 3 winding, w/sat | HYPERSIM doesn't support R1 <= 0, using R1 = 1E-6 L1 < 1E-6 pu, using L1 = 1E-6 pu R2 <= 0, using R2 = 1E-6 L2 < 1E-6 pu, using L2 = 1E-6 pu R3 <= 0, using R3 = 1E-6 L3 < 1E-6 pu, using L3 = 1E-6 pu Using Rm and Lm = 30000 pu for linear transformer Exported mask not supported |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter